EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates

Miguel Angel Lozada Rufino iD, Eulogia Isabel Zapata Peña iD, Gonzalo Manuel Delgado Valdiviezo, Rosa Gisela Ortiz Castillo iD, Grecia Xiomara Herrera Gavilan iD, David César Ardiles Saravia, Luis Alfredo Espinoza-Espinoza, Karina Silvana Gutiérrez-Valverde

Biosensors · 2026

DOI: 10.3390/bios16100544 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2026. Verfasst von Miguel Angel Lozada Rufino und 7 weiteren Autor:innen. Beteiligte Einrichtung: Functional Foods and Bioengineering Research Group, National University of Frontera, Av. San Hilarión No. 101, Sullana 20101, Peru. Hauptthemen laut MEDLINE: Cadmium, Mangifera, Persea. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universidad Nacional de Frontera, National University of Frontera.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cadmium contamination in fruits is a relevant food-safety concern because of its toxicity, environmental persistence, and potential transfer from agricultural soils to edible plant tissues. This study developed a screen-printed carbon electrode modified with graphene oxide and cysteamine (SPCE/GO–cysteamine) to determine Cd(II) by square-wave anodic stripping voltammetry (SWASV). Two surface-modification routes, GO-cysteamine and GO-rGO-cysteamine, and GO concentrations of 0.1, 0.2, and 0.5 mg mL−1 were compared by cyclic voltammetry. The direct GO-cysteamine route at 0.2 mg mL−1 produced the highest CV response among the tested conditions and was selected for Cd(II) determination. Raman spectroscopy FTIR spectroscopy and scanning electron microscopy were used to characterize the graphene-based materials employed during surface optimization. Cd(II) concentrations from 1 to 10 µg L−1 were experimentally evaluated; with a calculated LOQ of 0.74 µg L−1, the entire experimentally evaluated range of 1–10 µg L−1, with a sensitivity of 11.30 µA (µg L−1)−1, R2 = 0.9892, a limit of detection of 0.25 µg L−1 and a limit of quantification of 0.74 µg L−1. Fortified Kent mango and Hass avocado digestates also showed concentration-dependent responses, with R2 values of 0.9799 and 0.9788, respectively, and relative standard deviations below 5%. These results demonstrate the feasibility of the SPCE/GO–cysteamine platform for Cd(II) determination in digested fruit matrices and support its further development as a portable screening approach for food-quality control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CadmiumMangiferaPerseaGraphiteElectrodesCysteamineCarbonElectrochemical TechniquesBiosensing TechniquesLimit of Detection

Stichwörter der Autor:innen

CadmiumSWASVavocadocysteamineelectrochemical sensormangoreduced graphene oxide

Substanzen

CadmiumGraphiteCysteamineCarbongraphene oxide

Autor:innen und Institutionen

  • Functional Foods and Bioengineering Research Group, National University of Frontera, Av. San Hilarión No. 101, Sullana 20101, Peru.
  • Center of Natural and Human Sciences, Federal University of ABC, Santo André 09210-580, SP, Brazil.
  • Faculty of Engineering of Food Industries and Biotechnology, Academic Department of Food Industries Engineering, National University of Frontera, Av. San Hilarión No. 101, Sullana 20101, Peru.
  • 3R Aerospace & Nanotechnology, 38000 Grenoble, France.
  • Department of Engineering, National University of Barranca, Barranca 15169, Peru.

ORCID-Profile: Miguel Angel Lozada Rufino, Eulogia Isabel Zapata Peña, Rosa Gisela Ortiz Castillo, Grecia Xiomara Herrera Gavilan

Förderung

  • Universidad Nacional de Frontera
  • National University of Frontera

Zitieren

APA

Lozada Rufino, M. A., Zapata Peña, E. I., Delgado Valdiviezo, G. M., Ortiz Castillo, R. G., Herrera Gavilan, G. X., Ardiles Saravia, D. C., Espinoza-Espinoza, L. A., & Gutiérrez-Valverde, K. S. (2026). GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates. Biosensors. https://doi.org/10.3390/bios16100544

Vancouver

Lozada Rufino MA, Zapata Peña EI, Delgado Valdiviezo GM, Ortiz Castillo RG, Herrera Gavilan GX, Ardiles Saravia DC, et al. GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates. Biosensors. 2026. doi:10.3390/bios16100544

BibTeX
@article{LozadaRufino2026,
  author = {Lozada Rufino, Miguel Angel and Zapata Peña, Eulogia Isabel and Delgado Valdiviezo, Gonzalo Manuel and Ortiz Castillo, Rosa Gisela and Herrera Gavilan, Grecia Xiomara and Ardiles Saravia, David César and Espinoza-Espinoza, Luis Alfredo and Gutiérrez-Valverde, Karina Silvana},
  title = {GO/Cysteamine-Modified Screen-Printed Carbon Electrode for Square-Wave Anodic Stripping Voltammetric Determination of Cadmium in Fortified Mango and Avocado Digestates},
  journal = {Biosensors},
  year = {2026},
  doi = {10.3390/bios16100544}
}
Kostenlos starten →