EUVIMEDEUVIMED entdecken
Crossref

Robust estimation of Shear Wave group velocity for ultrasound elastography based on frequency domain analysis

Qian Lv, Xin Zhao, Liang Zhao, Ying Liu, Ye Tian, Jianzhong Guo

Medical Ultrasonography · 2024

DOI: 10.11152/mu-4464 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Ultrasonography, 2024. Verfasst von Qian Lv und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an. Hauptthemen laut MEDLINE: Elasticity Imaging Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

Shear wave elastography (SWE) is of great significance in measuring the elasticity and in evaluating mechanical properties of biological tissues. The elasticity of biological tissues can be reflected by measuring the propagation velocity of shear waves. Therefore, accurate estimation of shear wave velocity is crucial.Material and methods: In this study, we proposed a robust estimation method based on a cyclic shifting algorithm (CSA) for measuring shear wave group velocity in homogeneous media. To validate the utility of the algorithm, we conducted accuracy analysis and robustness analysis with different noise levels in the digital phantom used for the standardization of shear wave velocity by Quantitative Imaging Biomarker Alliance (QIBA) of the Radiological Society of North America.

Results

The estimated shear wave velocities (SWV) of the elastic digital phantoms with Young’s moduli 3 kPa, 6 kPa, 15 kPa, 30 kPa are 1.0156 m/s, 1.4065 m/s, 2.1875 m/s, 3.1250 m/s, respectively. When adding Gaussian white noise with 0 dB, the relative errors of the estimated SWVs are 2.5%, 4.8%, 11.8%, 20.5%, respectively. The estimated SWVs in the gelatin phantom with gelatin concentration of 7% and 10% are 2.0442 m/s and 3.1237 m/s. Compared with the existing two representative estimation algorithms, the estimation algorithm proposed in this paper has a higher anti-noise performance due to effective energy accumulation in the frequency domain.

Conclusions

The proposed SWV method based on CSA in frequency domain is a robust shear wave group velocity estimation method, which seems to be a useful tool in homogeneous media for ultrasound elastography.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elasticity Imaging TechniquesPhantoms, ImagingAlgorithmsReproducibility of ResultsHumansElastic Modulus

Autor:innen und Institutionen

  • Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an.
  • Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an. guojz@snnu.edu.cn.

Zitieren

APA

Lv, Q., Zhao, X., Zhao, L., Liu, Y., Tian, Y., & Guo, J. (2024). Robust estimation of Shear Wave group velocity for ultrasound elastography based on frequency domain analysis. Medical Ultrasonography. https://doi.org/10.11152/mu-4464

Vancouver

Lv Q, Zhao X, Zhao L, Liu Y, Tian Y, Guo J. Robust estimation of Shear Wave group velocity for ultrasound elastography based on frequency domain analysis. Medical Ultrasonography. 2024. doi:10.11152/mu-4464

BibTeX
@article{Lv2024,
  author = {Lv, Qian and Zhao, Xin and Zhao, Liang and Liu, Ying and Tian, Ye and Guo, Jianzhong},
  title = {Robust estimation of Shear Wave group velocity for ultrasound elastography based on frequency domain analysis},
  journal = {Medical Ultrasonography},
  year = {2024},
  doi = {10.11152/mu-4464}
}
Kostenlos starten →