WFUMB position paper on reverberation artefacts in lung ultrasound: B-lines or comet-tails?
Medical Ultrasonography · 18.02.2021 · 23 (1) · 70
DOI: 10.11152/mu-2944 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Medical Ultrasonography, online erschienen am 18.02.2021. Verfasst von Gebhard Mathis und 8 weiteren Autor:innen. Beteiligte Einrichtung: Rankweil, Austria. Hauptthemen laut MEDLINE: Lung Diseases, Pulmonary Edema, Ultrasonography. Die Arbeit wurde bisher 38-mal zitiert (Crossref).
Abstract (Originalsprache)
The analysis of vertical reverberation artefacts is an essential component of the differential diagnosis in pulmonary ultra-sound. Traditionally, they are often, but not exclusively, called B-line artefacts (BLA) and/or comet tail artefacts (CTA), but this view is misleading. In this position paper we clarify the terminology and relation of the two lung reverberation artefacts BLA and CTA to spe-cific clinical scenarios. BLA are defined by a normal pleura line and are a typical hallmark of cardiogenic pulmonary edema after exclusion of certain pathologies including pneumonia or lung contusion, whereas CTAs show an irregular pleura line representing a variety of parenchymal lung diseases. The dual approach using low frequency transducers to determine BLA and high frequency transducer to determine the pleural surface is recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Rankweil, Austria.
- Department of Emergency Medicine, Kantonspital Glarus, Switzerland.
- Intensive Care, Mastrils, Kanton Graubünden, Switzerland.
- Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Austria.
- Department of Emergency Medicine, Linköping University Hospital, Linköping, Sweden.
- Diagnostic and Interventional Ultrasound Unit, Valle del Serchio General Hospital, Lucca, Italy.
Zitieren
APA
Mathis, G., Horn, R., Morf, S., Prosch, H., Rovida, S., Soldati, G., Hoffmann, B., Blaivas, M., & Dietrich, C. F. (2021). WFUMB position paper on reverberation artefacts in lung ultrasound: B-lines or comet-tails?. Medical Ultrasonography, 23(1), 70. https://doi.org/10.11152/mu-2944
Vancouver
Mathis G, Horn R, Morf S, Prosch H, Rovida S, Soldati G, et al. WFUMB position paper on reverberation artefacts in lung ultrasound: B-lines or comet-tails?. Medical Ultrasonography. 2021;23(1):70. doi:10.11152/mu-2944
BibTeX
@article{Mathis2021,
author = {Mathis, Gebhard and Horn, Rudolf and Morf, Susanne and Prosch, Helmut and Rovida, Serena and Soldati, Gino and Hoffmann, Beatrice and Blaivas, Michael and Dietrich, Christoph F},
title = {WFUMB position paper on reverberation artefacts in lung ultrasound: B-lines or comet-tails?},
journal = {Medical Ultrasonography},
year = {2021},
volume = {23},
number = {1},
pages = {70},
doi = {10.11152/mu-2944}
}
EUVIMED