EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access

A Predictive Model Based on Cardio and Lung Ultrasound Features for Differential Diagnosis of Cardiogenic and Non‐cardiogenic Dyspnea in Patients With Chronic Kidney Disease: A Single‐Center Observational Study

Haotian Zhao iD, Ze Zhang, Ling Long iD, Yaru Yan, Zekai Wang, Li Li, Heling Zhao, Yuquan Ye iD

Journal of Ultrasound in Medicine · 2026

DOI: 10.1002/jum.70317 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Ultrasound in Medicine, 2026. Verfasst von Haotian Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound Medicine, Hebei Medical University, Shijiazhuang, China. Hauptthemen laut MEDLINE: Dyspnea, Renal Insufficiency, Chronic, Lung Diseases. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Lung ultrasound (LUS) quantifying B‐lines is valuable to assess fluid status during hemodialysis. However, B‐lines may indicate not only cardiogenic pulmonary edema (CPE) but also non‐cardiogenic pulmonary diseases, such as pneumonia or interstitial lung disease, posing challenges to guiding fluid therapy decisions. We developed a combined cardiac‐LUS diagnostic model to differentiate these etiologies, aiming to prevent misdiagnosis and optimize treatment.

Methods

This retrospective observational study enrolled chronic kidney disease (CKD) stage 3–5 patients divided into training and validation cohorts. Participants were classified into CPE group or non‐cardiogenic dyspnea (NCD) group. Multivariable logistic regression identified discriminative echocardiographic and LUS parameters to build a diagnostic model. Predictive performance was assessed using receiver operator characteristic (ROC), calibration and decision curve analysis. A simplified β‐weighted scoring system was developed and evaluated.

Results

This retrospective study analyzed 215 training and 56 validation participants. Multivariable regression identified E/e′ (OR 1.180, 95% CI 1.067–1.304, p = .001), inferior vena cava diameter (OR 1.240, 95% CI 1.023–1.503, p = .029), bilateral symmetric B‐pattern (OR 9.720, 95% CI 2.707–34.899, p < .001), bilateral continuous B‐pattern (OR 13.777, 95% CI 3.666–51.770, p < .001), ≥1 irregular pleural line region (OR 0.078, 95% CI 0.018–0.326, p < .001), ≥1 consolidation region (OR 0.039, 95% CI 0.008–0.196, p < .001), ≥1 pleural effusion region (OR 4.732, 95% CI 1.148–19.510, p = .032) as independent CPE predictors. The nomogram showed good discrimination, with area under the curve (AUC) of 0.9703 (training) and 0.8910 (validation). The β‐weighted scoring system (cut‐off as 42.99 scores) showed an AUC of 0.968 (training) and 0.888 (validation).

Conclusion

The nomogram model demonstrated that the ultrasound parameters and β‐weighted scoring system possess reliable clinical application value and high predictive accuracy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DyspneaRenal Insufficiency, ChronicLung DiseasesHumansRetrospective StudiesDiagnosis, DifferentialFemaleMaleUltrasonographyMiddle AgedAgedLungReproducibility of ResultsPredictive Value of TestsPulmonary EdemaHeart

Stichwörter der Autor:innen

cardiogenic pulmonary edemachronic kidney diseasediagnosislung ultrasoundnomogram

Autor:innen und Institutionen

  • Department of Ultrasound Medicine, Hebei Medical University, Shijiazhuang, China.
  • Department of Ultrasound, Hebei General Hospital, Shijiazhuang, China.
  • Department of Intensive Care Medicine, Hebei General Hospital, Shijiazhuang, China.
  • Department of Ultrasound, Shijiazhuang People's Hospital, Shijiazhuang, China.
  • Department of Nephrology, Hebei General Hospital, Shijiazhuang, China.

ORCID-Profile: Haotian Zhao, Ling Long, Yuquan Ye

Zitieren

APA

Zhao, H., Zhang, Z., Long, L., Yan, Y., Wang, Z., Li, L., Zhao, H., & Ye, Y. (2026). A Predictive Model Based on Cardio and Lung Ultrasound Features for Differential Diagnosis of Cardiogenic and Non‐cardiogenic Dyspnea in Patients With Chronic Kidney Disease: A Single‐Center Observational Study. Journal of Ultrasound in Medicine. https://doi.org/10.1002/jum.70317

Vancouver

Zhao H, Zhang Z, Long L, Yan Y, Wang Z, Li L, et al. A Predictive Model Based on Cardio and Lung Ultrasound Features for Differential Diagnosis of Cardiogenic and Non‐cardiogenic Dyspnea in Patients With Chronic Kidney Disease: A Single‐Center Observational Study. Journal of Ultrasound in Medicine. 2026. doi:10.1002/jum.70317

BibTeX
@article{Zhao2026,
  author = {Zhao, Haotian and Zhang, Ze and Long, Ling and Yan, Yaru and Wang, Zekai and Li, Li and Zhao, Heling and Ye, Yuquan},
  title = {A Predictive Model Based on Cardio and Lung Ultrasound Features for Differential Diagnosis of Cardiogenic and Non‐cardiogenic Dyspnea in Patients With Chronic Kidney Disease: A Single‐Center Observational Study},
  journal = {Journal of Ultrasound in Medicine},
  year = {2026},
  doi = {10.1002/jum.70317}
}
Kostenlos starten →