EUVIMEDEUVIMED entdecken
Evaluationsstudie

Design and Evaluation of an Integrated Piezoelectric Force Sensing Total Knee Replacement

Brandon D Hines, Ryan Willing, Steven R Anton iD

Journal of Biomechanical Engineering · 2026

DOI: 10.1115/1.4072435 ↗

Kurz gefasst

Evaluationsstudie in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Brandon D Hines und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical & Nuclear Engineering, Tennessee Technological University, 115 West 10th Street, Cookeville, TN 38505. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Mechanical Phenomena, Knee Prosthesis, Prosthesis Design. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 51 Literaturangaben. Gefördert von: NIAMS NIH HHS, National Institute of Arthritis and Musculoskeletal and Skin Diseases.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

With patient dissatisfaction rates in total knee arthroplasty currently at 20%, smart knee technology seeks to provide an in vivo method for tracking postoperative joint forces, which could aid in early diagnosis of postoperative complications and provide key data to help improve implant designs and surgical procedures. This study investigates the design, simulation, and experimental evaluation of a piezoelectric force sensing system integrated into a commercially available knee implant that preserves the overall implant geometry. Finite element simulation and parametric analysis are used to identify the transducer arrangement with the lowest error in sensing compartmental joint contact forces. A prototype is then subjected to an axial load profile simulating walking using a joint motion simulator. Total and compartmental contact forces are evaluated, and accuracy of compartmental center of pressure localization is evaluated via ±3 mm and ±6 mm anterior–posterior translations. Results show the ability to track the axial force profile and demonstrate center of pressure deviations of ∼1 mm or better at 3-A and 3-P translations and ∼3–4 mm at 6-A and 6-P translations. Error of the order of ∼15% is observed in the total force measurement at maximum load. Suspected sources of error include plastic deformation of the tibial bearing insert and high stress levels in the piezoelectric transducers that suggest partial depolarization. Overall, our piezoelectric smart knee replacement shows promise for in vivo joint sensing, and this work marks a path for further development for integration into commercial knee replacement components.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeMechanical PhenomenaKnee ProsthesisProsthesis DesignFinite Element AnalysisHumansBiomechanical PhenomenaEquipment Design

Stichwörter der Autor:innen

in vivo sensingjoint forcespiezoelectricsmart implanttibiofemoral contacttotal knee replacement

Autor:innen und Institutionen

  • Department of Mechanical & Nuclear Engineering, Tennessee Technological University, 115 West 10th Street, Cookeville, TN 38505.
  • Department of Mechanical and Materials Engineering, University of Western Ontario, 1151 Richmond Street, London, ON N6A 3K7, Canada.

ORCID-Profile: Steven R Anton

Förderung

  • NIAMS NIH HHS
  • National Institute of Arthritis and Musculoskeletal and Skin Diseases

Zitieren

APA

Hines, B. D., Willing, R., & Anton, S. R. (2026). Design and Evaluation of an Integrated Piezoelectric Force Sensing Total Knee Replacement. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4072435

Vancouver

Hines BD, Willing R, Anton SR. Design and Evaluation of an Integrated Piezoelectric Force Sensing Total Knee Replacement. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4072435

BibTeX
@article{Hines2026,
  author = {Hines, Brandon D and Willing, Ryan and Anton, Steven R},
  title = {Design and Evaluation of an Integrated Piezoelectric Force Sensing Total Knee Replacement},
  journal = {Journal of Biomechanical Engineering},
  year = {2026},
  doi = {10.1115/1.4072435}
}
Kostenlos starten →