Investigating Contact Models in Clavicle Fixation Plates: A Finite Element Study of Their Impact on Biomechanical Performance
Journal of Biomechanical Engineering · 2026
DOI: 10.1115/1.4072325 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, 2026. Verfasst von Abderrazak Kedadria und 2 weiteren Autor:innen. Beteiligte Einrichtung: Mechanical System Design Laboratory, Ecole Militaire Polytechnique, Boite Postale 17, Commune de Bordj El Bahri, Algiers 16046, Algeria. Hauptthemen laut MEDLINE: Finite Element Analysis, Clavicle, Bone Plates, Mechanical Phenomena. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 39 Literaturangaben.
Abstract (Originalsprache)
Clavicle fractures are among the most common orthopedic injuries and frequently require plate fixation to restore anatomical alignment and mechanical stability. The biomechanical performance of fixation constructs is strongly influenced by the contact interactions between the plate, bone, and screws. This study investigated the effect of four contact formulations (bonded, no-separation, frictionless, and frictional) on the structural stiffness, stress distribution, and interfragmentary strain of clavicle fixation plates using finite element analysis. A three-dimensional (3D) clavicle model reconstructed from computed tomography (CT) data was subjected to 200 N inferior bending, 200 N axial compression, and 4 N·m torsional loading. The bonded model exhibited the highest structural stiffness under all loading conditions (+66% bending, +60% compression, and +38% torsion relative to the intact model), but also generated high stress concentrations, reaching 620.3 MPa under bending. The frictional and frictionless models produced lower stiffness values (+64% bending, +16% compression, and +28% torsion), while the no-separation model demonstrated intermediate stiffness. Peak plate stress varied considerably among contact formulations, with the no-separation model producing the highest value under bending (655.3 MPa). Interfragmentary strain was lowest in the bonded model (<2%), whereas frictional and frictionless models generated higher strain levels (2–10%), corresponding to mechanical conditions associated with secondary healing. The no-separation model exhibited intermediate strain values. These findings demonstrate that contact conditions strongly influence the biomechanical behavior of clavicle fixation constructs. Incorporating physiologically realistic contact models may improve finite element predictions and support the optimization of fixation strategies and implant design.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Mechanical System Design Laboratory, Ecole Militaire Polytechnique, Boite Postale 17, Commune de Bordj El Bahri, Algiers 16046, Algeria.
- Department of Mechanics, Royal Military Academy, Avenue de la Renaissance 30, Brussels 1000, Belgium.
ORCID-Profile: Abderrazak Kedadria
Zitieren
APA
Kedadria, A., Gilson, L., & Rabet, L. (2026). Investigating Contact Models in Clavicle Fixation Plates: A Finite Element Study of Their Impact on Biomechanical Performance. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4072325
Vancouver
Kedadria A, Gilson L, Rabet L. Investigating Contact Models in Clavicle Fixation Plates: A Finite Element Study of Their Impact on Biomechanical Performance. Journal of Biomechanical Engineering. 2026. doi:10.1115/1.4072325
BibTeX
@article{Kedadria2026,
author = {Kedadria, Abderrazak and Gilson, Lionel and Rabet, Luc},
title = {Investigating Contact Models in Clavicle Fixation Plates: A Finite Element Study of Their Impact on Biomechanical Performance},
journal = {Journal of Biomechanical Engineering},
year = {2026},
doi = {10.1115/1.4072325}
}
EUVIMED