EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review

Radovan Zdero, Christopher Del Balso, Abdel-Rahman Lawendy, Emil H Schemitsch, Pawel Brzozowski iD

Journal of Biomechanical Engineering · 2025

DOI: 10.1115/1.4069593 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Radovan Zdero und 4 weiteren Autor:innen. Beteiligte Einrichtung: London Health Sciences Centre Research Institute, 800 Commissioners Road East, London, ON N6A-5W9, Canada. Hauptthemen laut MEDLINE: Bone Plates, Calcaneus, Fractures, Bone, Mechanical Phenomena. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 70 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This review article surveys all computational and experimental investigations that varied plate and/or screw variables to evaluate the mechanical effect on calcaneus (i.e., heel bone) fracture plates (CFPs). PubMed, Scopus, and Web of Science archives were examined for studies published on any date and in any language that (i) mechanically characterized the effect of changing plate and/or screw variables on CFP performance, rather than just comparing or augmenting CFPs with other types of implants and (ii) only analyzed calcaneus fractures, rather than other co-injuries of the ankle or foot. The 36 eligible studies evaluated various plate variables (i.e., geometry, hole type, number) and screw variables (i.e., geometry, number, distribution, angle), but not plate position or material. The studies reported engineering outcome metrics like (i) interfragmentary motion (0–11.24 mm; 0–1.20 deg), (ii) bone (2.6–502.6 MPa), plate (11.4–1084.0 MPa), or screw (19.7–524.5 MPa) stress, (iii) bone stress under the plate to evaluate “stress shielding” (0–50.0 MPa), (iv) the number of loading cycles to failure (1000–89,250 cycles), (v) overall stiffness (22–5108 N/mm), or (vi) failure strength (100–7867 N). This review also discusses future work for implant variables, bone variables, study methodologies, and clinical items, as well as recommending a particular CFP configuration for maximal mechanical stability. This review will help biomedical engineers and orthopedic surgeons to effectively design, analyze, or use CFPs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone PlatesCalcaneusFractures, BoneMechanical PhenomenaMaterials TestingMechanical TestsHumansBiomechanical PhenomenaFinite Element Analysis

Stichwörter der Autor:innen

biomechanicscalcaneusfractureplatesreview

Autor:innen und Institutionen

  • London Health Sciences Centre Research Institute, 800 Commissioners Road East, London, ON N6A-5W9, Canada.
  • Division of Orthopaedic Surgery, Western University, London, ON N6A 3K7, Canada.
  • Victoria Hospital.
  • Division of Orthopaedic Surgery, Western University, London, ON N6A 3K7, Canada; Centre for Critical Illness Research, Victoria Hospital, London, ON N6A-5W9, Canada.
  • London Health Sciences Centre Research Institute, 800 Commissioners Road East, London, ON N6A-5W9, Canada; Division of Orthopaedic Surgery, Western University, London, ON N6A 3K7, Canada.

ORCID-Profile: Pawel Brzozowski

Zitieren

APA

Zdero, R., Del Balso, C., Lawendy, A. R., Schemitsch, E. H., & Brzozowski, P. (2025). Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4069593

Vancouver

Zdero R, Del Balso C, Lawendy AR, Schemitsch EH, Brzozowski P. Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4069593

BibTeX
@article{Zdero2025,
  author = {Zdero, Radovan and Del Balso, Christopher and Lawendy, Abdel-Rahman and Schemitsch, Emil H and Brzozowski, Pawel},
  title = {Computational Modeling and Mechanical Testing of Calcaneus Fracture Plates: A Review},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  doi = {10.1115/1.4069593}
}
Kostenlos starten →