EUVIMEDEUVIMED entdecken
Validierungsstudie

Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses

Jason J Wiebrecht iD, Jacob A Strick iD, Ryan J Farris, Jerzy T Sawicki

Journal of Biomechanical Engineering · 2025

DOI: 10.1115/1.4068369 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Journal of Biomechanical Engineering, 2025. Verfasst von Jason J Wiebrecht und 3 weiteren Autor:innen. Beteiligte Einrichtung: Center for Rotating Machinery Dynamics and Control, Washkewicz College of Engineering, Cleveland State University, Cleveland, OH 44115. Hauptthemen laut MEDLINE: Orthotic Devices, Knee Joint, Mechanical Phenomena. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Robot-assisted gait rehabilitation is an increasingly common therapeutic intervention for enhancing locomotion and improving quality of life for children with lower-limb mobility impairments. However, there are few systems specifically designed for pediatric use, and those that do exist are largely cumbersome, bulky, and noncustom devices that ultimately reduce therapy effectiveness. This paper introduces the Cable-Driven Joint System (CDJS), a novel approach for pediatric gait rehabilitation that addresses these shortcomings in a lightweight and compact robotic device using the patient's professionally fitted orthosis. The CDJS consists of a 2.1 kg actuation unit that is held by a clinician which delivers assistive torques through a Bowden cable transmission to a 0.3 kg joint mounted to user-custom bracing. This work details an actuator benchtop evaluation, demonstrating a peak torque of 20 N·m, peak velocity of 7.2 rad/s, bandwidth of 9.7 Hz, and a mass moment of inertia of 58.38 kg cm2. An actuator model was developed and evaluated in simulation, showing a strong correlation with the experimental torque data (R-squared = 0.95) and indicating a transmission efficiency of 72%. In-air gait tracking experiments on an emulated subject showed that the CDJS assisted the subject to track a nominal knee trajectory with an average root-mean-squared error of 2.56 deg at a continuous torque of 1.37 N·m. These results suggest that the cable-driven actuator meets the design requirements for use in pediatric gait rehabilitation and is ready for implementation in clinical device trials.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthotic DevicesKnee JointMechanical PhenomenaEquipment DesignHumansTorqueChildGaitBiomechanical PhenomenaRobotics

Stichwörter der Autor:innen

cable-driven actuatorexoskeletongait rehabilitationlower-limbrobotic orthosis

Autor:innen und Institutionen

  • Center for Rotating Machinery Dynamics and Control, Washkewicz College of Engineering, Cleveland State University, Cleveland, OH 44115.
  • Department of Engineering, Messiah University, Mechanicsburg, PA 17055.

ORCID-Profile: Jason J Wiebrecht, Jacob A Strick

Zitieren

APA

Wiebrecht, J. J., Strick, J. A., Farris, R. J., & Sawicki, J. T. (2025). Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4068369

Vancouver

Wiebrecht JJ, Strick JA, Farris RJ, Sawicki JT. Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses. Journal of Biomechanical Engineering. 2025. doi:10.1115/1.4068369

BibTeX
@article{Wiebrecht2025,
  author = {Wiebrecht, Jason J and Strick, Jacob A and Farris, Ryan J and Sawicki, Jerzy T},
  title = {Design and Validation of a Cable-Driven Joint Actuator for Pediatric Knee Orthoses},
  journal = {Journal of Biomechanical Engineering},
  year = {2025},
  doi = {10.1115/1.4068369}
}
Kostenlos starten →