The effect of carbon fiber custom dynamic orthosis type on kinematics and kinetics of lower extremity joints in individuals with lower limb traumatic injuries
Gait & Posture · 2025
DOI: 10.1016/j.gaitpost.2024.12.024 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Gait & Posture, 2025. Verfasst von Sapna Sharma und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, University of Iowa, Iowa City, IA, USA. Electronic address: sa…. Hauptthemen laut MEDLINE: Orthotic Devices, Leg Injuries, Carbon. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCATS NIH HHS, National Institutes of Health, US Department of Defense.
Abstract (Originalsprache)
BACKGROUND: Carbon fiber custom dynamic orthoses have been used to improve gait mechanics after lower limb trauma in military service members, with the goal of restoring function and improving outcomes. However, the effects of commercially available carbon fiber orthoses available to civilians on lower extremity joint kinetics and kinematics are poorly understood. RESEARCH QUESTION: The aim of this study was to examine the effect of two commercially available orthoses on lower extremity kinematics and kinetics in individuals with lower limb trauma. METHODS: A total of 23 participants with a lower extremity traumatic injury underwent gait analysis while walking without an orthosis, and while wearing a monolithic carbon fiber orthosis or while wearing a modular carbon fiber orthosis, in a randomized order. Study participants accommodated to each orthosis for three months prior to testing. Joint kinematics and kinetics at the ankle, knee, and hip joints, and ground reaction forces were assessed. RESULTS: The two study orthoses significantly reduced ankle motion compared to no orthosis, with large effect sizes observed. Peak plantarflexor moment was greater with the modular orthosis compared to the monolithic orthosis. Ankle push-off power did not differ between orthoses but was significantly reduced relative to no orthosis. Push-off power with the study orthoses was over 25% greater as compared to previous studies with military orthoses. Peak loading response power generation at the knee was greater with the monolithic orthosis as compared to the modular orthosis. The kinematics and kinetics at the hip did not differ between orthoses. SIGNIFICANCE: Orthoses commonly used in civilian settings to treat limb trauma primarily alter joint kinematics and kinetics at the ankle, in a manner consistent with orthoses used in the military. Additionally, despite the apparent large differences in the designs of the two study orthoses, between-orthosis differences on gait mechanics were limited.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, University of Iowa, Iowa City, IA, USA. Electronic address: sapna-sharma@uiowa.edu.
- Department of Physical Therapy and Rehabilitation Science, Carver College of Medicine, University of Iowa, Iowa City, IA, USA.
- Rehabilitation and Engineering Center for Optimizing Veteran Engagement and Reintegration (RECOVER), Minneapolis Veterans Affairs Health Care System, Minneapolis, MN, USA; Department of Family Medicine and Community Hea…
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD, USA; Henry M. Jackson Foundation for the Advancement of Military Medicine, Inc., Bethesda, MD, USA.
- Department of Rehabilitation, Walter Reed National Military Medical Center, Bethesda, MD, USA; Extremity Trauma and Amputation Center of Excellence, Defense Health Agency, Falls Church, VA, USA.
Förderung
- NCATS NIH HHS
- National Institutes of Health
- US Department of Defense
- Henry M. Jackson Foundation
- U.S. Air Force
- National Center for Advancing Translational Sciences
Zitieren
APA
Sharma, S., Anderson, K. M., Pacha, M. S., Falbo, K. J., Severe, C., Hansen, A. H., Hendershot, B. D., Wilken, J. M., & CARBon fiber Orthosis research Network (CARBON) (2025). The effect of carbon fiber custom dynamic orthosis type on kinematics and kinetics of lower extremity joints in individuals with lower limb traumatic injuries. Gait & Posture. https://doi.org/10.1016/j.gaitpost.2024.12.024
Vancouver
Sharma S, Anderson KM, Pacha MS, Falbo KJ, Severe C, Hansen AH, et al. The effect of carbon fiber custom dynamic orthosis type on kinematics and kinetics of lower extremity joints in individuals with lower limb traumatic injuries. Gait & Posture. 2025. doi:10.1016/j.gaitpost.2024.12.024
BibTeX
@article{Sharma2025,
author = {Sharma, Sapna and Anderson, Kirsten M and Pacha, Molly S and Falbo, Kierra J and Severe, Clare and Hansen, Andrew H and Hendershot, Brad D and Wilken, Jason M and CARBon fiber Orthosis research Network (CARBON), CARBon fiber Orthosis research Network (CARBON)},
title = {The effect of carbon fiber custom dynamic orthosis type on kinematics and kinetics of lower extremity joints in individuals with lower limb traumatic injuries},
journal = {Gait & Posture},
year = {2025},
doi = {10.1016/j.gaitpost.2024.12.024}
}
EUVIMED