Paediatric Prosthetic Knee Design: The Technical Requirements of a Swing Phase Control Mechanism Are Correlated With Parameters of Childhood Growth
IEEE Transactions on Biomedical Engineering · 2024
DOI: 10.1109/tbme.2024.3434477 ↗Kurz gefasst
Fachartikel in der Zeitschrift IEEE Transactions on Biomedical Engineering, 2024. Verfasst von Caitlin E Edgar und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Prosthesis Design, Knee Prosthesis, Gait, Knee Joint. Die Arbeit nennt 51 Literaturangaben. Gefördert von: Engineering and Physical Sciences Research Council, Doctoral Training in Prosthetics and Orthotics and the Department of Bioengineering, Imperial College London.
Abstract (Originalsprache)
OBJECTIVE: There is a lack of innovation in affordable prosthetic knee joints for children. One significant reason is the absence of technical requirements which consider the foundation of childhood: growth. This study aims to develop and use a modelling tool to determine the technical requirements throughout childhood growth for one prosthetic knee design feature, a swing phase control mechanism (SPCM). METHODS: 3D gait data of 31 non-disabled children across a range of physical maturities were analyzed. For each participant 2 models were created from a validated paediatric non-disabled musculoskeletal model. The model was first linearly scaled, then a corresponding unilateral right knee-disarticulation amputation model produced by removing segments below the knee and replacing with prosthetic componentry. Long established low-cost prosthetic componentry and a novel polycentric knee were implemented. For each participant, inverse dynamics were conducted and the SPCM torque requirements defined. RESULTS: Prosthetic knee SPCM torque requirements were significantly less than the non-disabled knee to emulate non-disabled gait at free speed: 17.9% (± 10.2) and 66.3% (± 17.0) reduction in maximum extension and flexion torque, respectively. Maximum knee extension torque showed the strongest negative correlation with intact body mass (ρ = -0.6251) whereas flexion torque showed the strongest correlation with height (ρ = 0.6611). Corresponding linear regression fits produced RMSE of 1.91and 1.73 Nm, respectively. Results were also determined for slow and fast speeds. CONCLUSION: The torque requirements of an affordable paediatric prosthetic knee SPCM are defined and found to strongly correlate with parameters of childhood growth (body mass, height, and age). SIGNIFICANCE: Current results recommend low-cost paediatric prosthetic SPCM designs can be tailored to accommodate growth. The creation of musculoskeletal models facilitate multiple future studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Förderung
- Engineering and Physical Sciences Research Council
- Doctoral Training in Prosthetics and Orthotics and the Department of Bioengineering
- Imperial College London
Zitieren
APA
Edgar, C. E., Jones, R. K., & Bull, A. M. J. (2024). Paediatric Prosthetic Knee Design: The Technical Requirements of a Swing Phase Control Mechanism Are Correlated With Parameters of Childhood Growth. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2024.3434477
Vancouver
Edgar CE, Jones RK, Bull AMJ. Paediatric Prosthetic Knee Design: The Technical Requirements of a Swing Phase Control Mechanism Are Correlated With Parameters of Childhood Growth. IEEE Transactions on Biomedical Engineering. 2024. doi:10.1109/tbme.2024.3434477
BibTeX
@article{Edgar2024,
author = {Edgar, Caitlin E and Jones, Richard K and Bull, Anthony M J},
title = {Paediatric Prosthetic Knee Design: The Technical Requirements of a Swing Phase Control Mechanism Are Correlated With Parameters of Childhood Growth},
journal = {IEEE Transactions on Biomedical Engineering},
year = {2024},
doi = {10.1109/tbme.2024.3434477}
}
EUVIMED