Biomechanical Response of Head Surrogate With and Without the Helmet
Journal of Biomechanical Engineering · 01.03.2024 · 146 (3)
DOI: 10.1115/1.4062968 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biomechanical Engineering, online erschienen am 29.01.2024. Verfasst von Abhilash Singh und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India. Hauptthemen laut MEDLINE: Head Protective Devices, Head. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 78 Literaturangaben. Gefördert von: Science and Engineering Research Board.
Abstract (Originalsprache)
Measurements of brain deformations under injurious loading scenarios are actively sought. In this work, we report experimentally measured head kinematics and corresponding dynamic, two-dimensional brain simulant deformations in head surrogates under a blunt impact, with and without a helmet. Head surrogates used in this work consisted of skin, skull, dura, falx, tentorium, and brain stimulants. The head surrogate geometry was based on the global human body models consortium's head model. A base head surrogate consisting of skin-skull-brain was considered. In addition, the response of two other head surrogates, skin-skull-dura-brain, and skin-skull-dura-brain-falx-tentorium, was investigated. Head surrogate response was studied for sagittal and coronal plane rotations for impactor velocities of 1 and 3 m/s. Response of head surrogates was compared against strain measurements in PMHS. The strain pattern in the brain simulant was heterogenous, and peak strains were established within ∼30 ms. The choice of head surrogate affect the spatiotemporal evolution of strain. For no helmet case, peak MPS of ∼50–60% and peak MSS of ∼35–50% were seen in brain simulant corresponding to peak rotational accelerations of ∼5000–7000 rad/s2. Peak head kinematics and peak MPS have been reduced by up to 75% and 45%, respectively, with the conventional helmet and by up to 90% and 85%, respectively, with the helmet with antirotational pads. Overall, these results provide important, new data on brain simulant strains under a variety of loading scenarios—with and without the helmets.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India.
- Department of Mechanical and Industrial Engineering, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667, India; Department of Design, Indian Institute of Technology Roorkee, Roorkee, Uttarakhand 247667,…
ORCID-Profile: Devendra Kumar
Förderung
- Science and Engineering Research Board
Zitieren
APA
Singh, A., Kumar, D., & Ganpule, S. (2024). Biomechanical Response of Head Surrogate With and Without the Helmet. Journal of Biomechanical Engineering, 146(3). https://doi.org/10.1115/1.4062968
Vancouver
Singh A, Kumar D, Ganpule S. Biomechanical Response of Head Surrogate With and Without the Helmet. Journal of Biomechanical Engineering. 2024;146(3). doi:10.1115/1.4062968
BibTeX
@article{Singh2024,
author = {Singh, Abhilash and Kumar, Devendra and Ganpule, Shailesh},
title = {Biomechanical Response of Head Surrogate With and Without the Helmet},
journal = {Journal of Biomechanical Engineering},
year = {2024},
volume = {146},
number = {3},
doi = {10.1115/1.4062968}
}