Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions
Experimental Physiology · 2025
DOI: 10.1113/ep092252 ↗At a glance
Journal article in Experimental Physiology, 2025. Written by Jedd Pratt and 3 co-authors. Institution: Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK. Major MEDLINE topics: Creatine, Brain, Proton Magnetic Resonance Spectroscopy. Cited 12 times so far (Crossref); 46 references. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Using proton magnetic resonance spectroscopy ( 1 H MRS) to determine total creatine (tCr) concentrations will become increasingly prevalent, as the role of creatine (Cr) in supporting brain health gains interest. Methodological limitations and margins of error in repeated 1 H MRS, which often surpass reported effects of supplementation, permeate existing literature. We examined the intra‐ and inter‐session reliability and repeatability of 1 H MRS for determining tCr concentrations across multiple brain regions (midbrain, visual cortex and frontal cortex). Eighteen healthy adults aged 20–32 years were recruited (50% female; n = 14 intra‐session; n = 15 inter‐session). 1 H Magnetic resonance imaging and spectroscopy were completed at 3 T. Intra‐session analyses involved repeated 1 H MRS of the midbrain, visual cortex and frontal cortex without participant or voxel repositioning, whereas inter‐session analyses involved measurements of the same regions, but with participant and voxel repositioning between repeated measurements. The 1 H MRS data (174 spectra) were analysed using TARQUIN and OSPREY, and voxel fractions (grey/white matter and CSF) were determined using segmentation. Our findings show that tCr concentrations can be determined reliably and repeatably using 1 H MRS, within an error of
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK.
- Department of Allied Health Professions and Sport and Exercise Science, School of Human and Health Sciences, University of Huddersfield, Huddersfield, UK.
ORCID profiles: Jedd Pratt, James McStravick, Craig Sale
Cite
APA
Pratt, J., McStravick, J., Kennerley, A. J., & Sale, C. (2025). Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. https://doi.org/10.1113/ep092252
Vancouver
Pratt J, McStravick J, Kennerley AJ, Sale C. Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. 2025. doi:10.1113/ep092252
BibTeX
@article{Pratt2025,
author = {Pratt, Jedd and McStravick, James and Kennerley, Aneurin J and Sale, Craig},
title = {Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions},
journal = {Experimental Physiology},
year = {2025},
doi = {10.1113/ep092252}
}
EUVIMED