EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions

Jedd Pratt iD, James McStravick iD, Aneurin J Kennerley, Craig Sale iD

Experimental Physiology · 2025

DOI: 10.1113/ep092252 ↗

At a glance

Journal article in Experimental Physiology, 2025. Written by Jedd Pratt and 3 co-authors. Institution: Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK. Major MEDLINE topics: Creatine, Brain, Proton Magnetic Resonance Spectroscopy. Cited 12 times so far (Crossref); 46 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Using proton magnetic resonance spectroscopy ( 1 H MRS) to determine total creatine (tCr) concentrations will become increasingly prevalent, as the role of creatine (Cr) in supporting brain health gains interest. Methodological limitations and margins of error in repeated 1 H MRS, which often surpass reported effects of supplementation, permeate existing literature. We examined the intra‐ and inter‐session reliability and repeatability of 1 H MRS for determining tCr concentrations across multiple brain regions (midbrain, visual cortex and frontal cortex). Eighteen healthy adults aged 20–32 years were recruited (50% female; n = 14 intra‐session; n = 15 inter‐session). 1 H Magnetic resonance imaging and spectroscopy were completed at 3 T. Intra‐session analyses involved repeated 1 H MRS of the midbrain, visual cortex and frontal cortex without participant or voxel repositioning, whereas inter‐session analyses involved measurements of the same regions, but with participant and voxel repositioning between repeated measurements. The 1 H MRS data (174 spectra) were analysed using TARQUIN and OSPREY, and voxel fractions (grey/white matter and CSF) were determined using segmentation. Our findings show that tCr concentrations can be determined reliably and repeatably using 1 H MRS, within an error of

Subjects

MeSH terms (MEDLINE)

CreatineBrainProton Magnetic Resonance SpectroscopyHumansFemaleAdultMaleYoung AdultReproducibility of ResultsMagnetic Resonance Imaging

Author keywords

braincreatinemagnetic resonance spectroscopyreliabilityreproducibility

Substances

Creatine

Authors and institutions

  • Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK.
  • Department of Allied Health Professions and Sport and Exercise Science, School of Human and Health Sciences, University of Huddersfield, Huddersfield, UK.

ORCID profiles: Jedd Pratt, James McStravick, Craig Sale

Cite

APA

Pratt, J., McStravick, J., Kennerley, A. J., & Sale, C. (2025). Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. https://doi.org/10.1113/ep092252

Vancouver

Pratt J, McStravick J, Kennerley AJ, Sale C. Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. 2025. doi:10.1113/ep092252

BibTeX
@article{Pratt2025,
  author = {Pratt, Jedd and McStravick, James and Kennerley, Aneurin J and Sale, Craig},
  title = {Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions},
  journal = {Experimental Physiology},
  year = {2025},
  doi = {10.1113/ep092252}
}
Start for free →