The Impact and Reliability of Tissue Segmentation on In Vivo Magnetic Resonance Spectroscopy Metabolite Quantification
Magnetic Resonance in Medicine · 2026
DOI: 10.1002/mrm.70380 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Jessica Archibald und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Weill Cornell Medicine, New York, New York, USA. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NIH HHS, NIBIB NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Purpose
Quantification of metabolite concentrations using MRS requires tissue‐dependent signal corrections. Accurate estimation of voxel tissue composition is therefore essential. Commonly used brain tissue segmentation tools differ in their algorithms and implementation, potentially introducing variability in MRS‐derived concentration estimates. This study investigates the impact and reliability of tissue segmentation on metabolite quantification.
Methods
Three segmentation tools (ANTs, FSL, SPM) were evaluated using an in vivo test–retest MRI/MRS dataset. Voxelwise GM/WM/CSF fractions were applied to compute tissue‐corrected total creatine (tCr) concentrations. Linear mixed‐effects modeling, variance‐component partitioning, and intraclass correlation coefficients (ICCs) quantified tool‐, session‐, and participant‐related variance under permutation scenarios that isolated segmentation‐ and MRS‐related effects. As a benchmark for segmentation performance, comparisons with manually segmented data were conducted across three brain regions.
Results
Segmentation tools produced systematically different tissue fractions that propagated into differences in tCr concentration estimates. Variance partitioning attributed 56.8%, 50.0%, and 51.3% of total tCr concentration variability to segmentation tool across the three permutations, with participant‐specific factors accounting for 34.7%, 36.2%, and 28.5%, respectively. When segmentation variability was held constant, test–retest reliability was high (ICC > 0.8) but dropped to ∼0.5 when both segmentation and MRS variability varied. Agreement with manual segmentation was region‐ and tool‐dependent, with the lowest agreement in the thalamus.
Conclusion
Tissue segmentation contributes substantially to the variability in MRS‐derived metabolite concentration estimates. These results underscore the need for transparent segmentation reporting and data sharing to ensure reproducibility and cross‐study comparability in MRS research.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Weill Cornell Medicine, New York, New York, USA.
- Department of Biomedical Engineering, Columbia University Fu Foundation School of Engineering and Applied Science, New York, New York, USA.
- CIBM Center for Biomedical Imaging, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
- Regeneron Genetics Center, Tarrytown, New York, USA.
- Department of Anesthesiology, Pharmacology and Therapeutics, Faculty of Medicine, University of British Columbia, Vancouver, British Columbia, Canada.
- The Malone Center for Engineering in Healthcare, Johns Hopkins University, Baltimore, Maryland, USA.
ORCID-Profile: Jessica Archibald, Kay Chioma Igwe, Karl Landheer, Jaimie Lee, Aaron T Gudmundson, Helge J Zöllner, Georg Oeltzschner, Candace C Fleischer, Jamie Near, Mark Mikkelsen
Förderung
- NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Archibald, J., Igwe, K. C., Kaiser, A., Landheer, K., Lee, J., Kramer, J. L. K., Gudmundson, A. T., Zöllner, H. J., Oeltzschner, G., Fleischer, C. C., Zölch, N., Near, J., & Mikkelsen, M. (2026). The Impact and Reliability of Tissue Segmentation on In Vivo Magnetic Resonance Spectroscopy Metabolite Quantification. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70380
Vancouver
Archibald J, Igwe KC, Kaiser A, Landheer K, Lee J, Kramer JLK, et al. The Impact and Reliability of Tissue Segmentation on In Vivo Magnetic Resonance Spectroscopy Metabolite Quantification. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70380
BibTeX
@article{Archibald2026,
author = {Archibald, Jessica and Igwe, Kay Chioma and Kaiser, Antonia and Landheer, Karl and Lee, Jaimie and Kramer, John L K and Gudmundson, Aaron T and Zöllner, Helge J and Oeltzschner, Georg and Fleischer, Candace C and Zölch, Niklaus and Near, Jamie and Mikkelsen, Mark},
title = {The Impact and Reliability of Tissue Segmentation on In Vivo Magnetic Resonance Spectroscopy Metabolite Quantification},
journal = {Magnetic Resonance in Medicine},
year = {2026},
doi = {10.1002/mrm.70380}
}
EUVIMED