Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions
Experimental Physiology · 2025
DOI: 10.1113/ep092252 ↗Kurz gefasst
Fachartikel in der Zeitschrift Experimental Physiology, 2025. Verfasst von Jedd Pratt und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK. Hauptthemen laut MEDLINE: Creatine, Brain, Proton Magnetic Resonance Spectroscopy. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Using proton magnetic resonance spectroscopy ( 1 H MRS) to determine total creatine (tCr) concentrations will become increasingly prevalent, as the role of creatine (Cr) in supporting brain health gains interest. Methodological limitations and margins of error in repeated 1 H MRS, which often surpass reported effects of supplementation, permeate existing literature. We examined the intra‐ and inter‐session reliability and repeatability of 1 H MRS for determining tCr concentrations across multiple brain regions (midbrain, visual cortex and frontal cortex). Eighteen healthy adults aged 20–32 years were recruited (50% female; n = 14 intra‐session; n = 15 inter‐session). 1 H Magnetic resonance imaging and spectroscopy were completed at 3 T. Intra‐session analyses involved repeated 1 H MRS of the midbrain, visual cortex and frontal cortex without participant or voxel repositioning, whereas inter‐session analyses involved measurements of the same regions, but with participant and voxel repositioning between repeated measurements. The 1 H MRS data (174 spectra) were analysed using TARQUIN and OSPREY, and voxel fractions (grey/white matter and CSF) were determined using segmentation. Our findings show that tCr concentrations can be determined reliably and repeatably using 1 H MRS, within an error of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Sport and Exercise Sciences, Manchester Metropolitan University Institute of Sport, Manchester, UK.
- Department of Allied Health Professions and Sport and Exercise Science, School of Human and Health Sciences, University of Huddersfield, Huddersfield, UK.
ORCID-Profile: Jedd Pratt, James McStravick, Craig Sale
Zitieren
APA
Pratt, J., McStravick, J., Kennerley, A. J., & Sale, C. (2025). Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. https://doi.org/10.1113/ep092252
Vancouver
Pratt J, McStravick J, Kennerley AJ, Sale C. Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions. Experimental Physiology. 2025. doi:10.1113/ep092252
BibTeX
@article{Pratt2025,
author = {Pratt, Jedd and McStravick, James and Kennerley, Aneurin J and Sale, Craig},
title = {Intra‐ and inter‐session reliability and repeatability of 1 H magnetic resonance spectroscopy for determining total creatine concentrations in multiple brain regions},
journal = {Experimental Physiology},
year = {2025},
doi = {10.1113/ep092252}
}
EUVIMED