EUVIMEDSkopri EUVIMED
ValidierungsstudieOpen access · CC BY 4.0

A refined, minimally invasive, reproducible ovine ischaemia–reperfusion–infarction model using implantable defibrillators: Methodology and validation

Charlene Pius iD, Barbara Niort iD, Emma J Radcliffe iD, Andrew W Trafford iD

Experimental Physiology · 2025

DOI: 10.1113/ep091760 ↗

At a glance

Validierungsstudie in Experimental Physiology, 2025. Written by Charlene Pius and 3 co-authors. Institution: Division of Cardiovascular Science, School of Medical Science, Faculty of Biology Medicine and Health, University of Manchester, Manchester Academic …. Major MEDLINE topics: Myocardial Infarction, Myocardial Reperfusion Injury, Defibrillators, Implantable. Cited 1 times so far (Crossref); 80 references. The full text is freely available (open access, CC BY 4.0). Funded by: The British Heart Foundation, Medical Research Council.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Ischaemic heart disease remains a leading cause of premature mortality and morbidity. Understanding the associated pathophysiological mechanisms of cardiac dysfunction arising from ischaemic heart disease and the identification of sites for new therapeutic interventions requires a preclinical model that reproduces the key clinical characteristics of myocardial ischaemia, reperfusion and infarction. Here, we describe and validate a refined and minimally invasive translationally relevant approach to induce ischaemia, reperfusion and infarction in the sheep. The novelty and refinement in the procedure stems from utilization of implantable cardiac defibrillators prior to coronary engagement, balloon angioplasty to induce infarction, and intra‐operative anti‐arrhythmic drug protocols to reduce adverse arrhythmic events. The protocol is readily adoptable by researchers with access to standard fluoroscopic instrumentation, and it requires minimally invasive surgery. These refinements lead to a substantial reduction of intra‐operative mortality to 6.7% from previously published values ranging between 13% and 43%. The model produces key characteristics associated with the fourth universal definition of myocardial infarction, including ECG changes, elevated cardiac biomarkers and cardiac wall motility defects. In conclusion, the model closely replicates the clinical paradigm of myocardial ischaemia, reperfusion and infarction in a translationally relevant large animal setting, and the applied refinements reduce the incidence of intra‐operative mortality typically associated with preclinical myocardial infarction models.

Subjects

MeSH terms (MEDLINE)

Myocardial InfarctionMyocardial Reperfusion InjuryDefibrillators, ImplantableAnimalsSheepDisease Models, AnimalFemaleElectrocardiographyMinimally Invasive Surgical ProceduresReproducibility of Results

Author keywords

echocardiographyelectrocardiographyheart diseaseinfarctionischaemiareperfusiontroponin

Authors and institutions

  • Division of Cardiovascular Science, School of Medical Science, Faculty of Biology Medicine and Health, University of Manchester, Manchester Academic Health Science Centre, Manchester, UK.

ORCID profiles: Charlene Pius, Barbara Niort, Emma J Radcliffe, Andrew W Trafford

Funding

  • The British Heart Foundation
  • Medical Research Council

Cite

APA

Pius, C., Niort, B., Radcliffe, E. J., & Trafford, A. W. (2025). A refined, minimally invasive, reproducible ovine ischaemia–reperfusion–infarction model using implantable defibrillators: Methodology and validation. Experimental Physiology. https://doi.org/10.1113/ep091760

Vancouver

Pius C, Niort B, Radcliffe EJ, Trafford AW. A refined, minimally invasive, reproducible ovine ischaemia–reperfusion–infarction model using implantable defibrillators: Methodology and validation. Experimental Physiology. 2025. doi:10.1113/ep091760

BibTeX
@article{Pius2025,
  author = {Pius, Charlene and Niort, Barbara and Radcliffe, Emma J and Trafford, Andrew W},
  title = {A refined, minimally invasive, reproducible ovine ischaemia–reperfusion–infarction model using implantable defibrillators: Methodology and validation},
  journal = {Experimental Physiology},
  year = {2025},
  doi = {10.1113/ep091760}
}
Start for free →