EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Spectral changes in skin blood flow during pressure manipulations or sympathetic stimulation

Natalia S Lima, Yi-Ting Tzen, Philip S Clifford

Experimental Physiology · 2024

DOI: 10.1113/ep091706 ↗

At a glance

Journal article in Experimental Physiology, 2024. Written by Natalia S Lima and 2 co-authors. Institution: Integrative Physiology Laboratory, University of Illinois at Chicago, Chicago, Illinois, USA. Major MEDLINE topics: Skin, Laser-Doppler Flowmetry, Regional Blood Flow, Sympathetic Nervous System. Cited 4 times so far (Crossref); 42 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Skin blood flow is commonly determined by laser Doppler flowmetry (LDF). It has been suggested that pathophysiological conditions can be assessed by analysis of specific frequency domains of the LDF signals. We tested whether physiological stimuli that activate myogenic and neurogenic mechanisms would affect relevant portions of the laser Doppler spectrum. LDF sensors were placed on the right forearm of 14 healthy volunteers for myogenic (six females) and 13 for neurogenic challenge (five females). Myogenic responses were tested by positioning the arm ∼50° above/below heart level. Neurogenic responses were tested by immersing the left hand into an ice slurry with and without topical application of local anaesthetic. Short‐time Fourier analyses were computed over the range of 0.06 to 0.15 Hz for myogenic and 0.02 to 0.06 Hz for neurogenic. No significant differences in spectral density were observed ( P = 0.40) in the myogenic range with arm above (7 ± 54 × 10 −4 dB) and below heart (7 ± 14 × 10 −4 dB). Neurogenic spectral density showed no significant increase from baseline to cold pressor test (0.0017 ± 0.0013 and 0.0038 ± 0.0039 dB; P = 0.087, effect size 0.47). After application of anaesthetic, neurogenic spectral density was unchanged between the baseline and cold pressor test (0.0014 ± 0.0025 and 0.0006 ± 0.0005 dB; P = 0.173). These results suggest that changes in the myogenic and neurogenic spectral density of LDF signals did not fully reflect the skin vascular function activated by pressure manipulation and sympathetic stimulation. Therefore, LDF myogenic and neurogenic spectral density data should be interpreted with caution.

Subjects

MeSH terms (MEDLINE)

SkinLaser-Doppler FlowmetryRegional Blood FlowSympathetic Nervous SystemHumansFemaleMaleAdultYoung AdultForearmCold TemperaturePressureAnesthetics, LocalBlood Pressure

Author keywords

myogenicneurogenicshort‐time Fourier transformationspectral analysis

Substances

Anesthetics, Local

Authors and institutions

  • Integrative Physiology Laboratory, University of Illinois at Chicago, Chicago, Illinois, USA.
  • University of Texas Southwestern Medical Center, Dallas, Texas, USA.

Cite

APA

Lima, N. S., Tzen, Y. T., & Clifford, P. S. (2024). Spectral changes in skin blood flow during pressure manipulations or sympathetic stimulation. Experimental Physiology. https://doi.org/10.1113/ep091706

Vancouver

Lima NS, Tzen YT, Clifford PS. Spectral changes in skin blood flow during pressure manipulations or sympathetic stimulation. Experimental Physiology. 2024. doi:10.1113/ep091706

BibTeX
@article{Lima2024,
  author = {Lima, Natalia S and Tzen, Yi-Ting and Clifford, Philip S},
  title = {Spectral changes in skin blood flow during pressure manipulations or sympathetic stimulation},
  journal = {Experimental Physiology},
  year = {2024},
  doi = {10.1113/ep091706}
}
Start for free →