Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study
Veterinary Surgery · 2026-11 · 55 (8) · 1340-1353
DOI: 10.1111/vsu.70166 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, online erschienen am 05.10.2026. Verfasst von Machiel P Ysebaert und 6 weiteren Autor:innen. Beteiligte Einrichtung: Colorado State University, College of Veterinary Medicine and Biomedical Sciences, Fort Collins, Colorado, USA. Hauptthemen laut MEDLINE: Cervical Vertebrae. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: American College of Veterinary Surgeons Foundation.
Abstract (Originalsprache)
Objective
To determine the biomechanical properties and modes of failure of a single level equine cervical spine immobilized with unilateral or bilateral articular process joint (APJ) stabilization, ventral cervical stabilization (VCS) and non‐stabilized controls. Study design Ex vivo experimental study. Sample population A total of 24 equine cadaver cervical spines.
Methods
Cervical spinal units (C4–C5) were randomly assigned to four groups ( n = 6/group): unilateral APJ stabilization, bilateral APJ stabilization, VCS using pedicle screws and rod constructs, or non‐stabilized. Non‐destructive testing assessed kinematic range of motion (ROM), neutral zone, and stiffness in flexion‐extension, axial rotation, and lateral bending. Specimens underwent four‐point bending to failure (0.1 mm/s). Radiographs and visual inspection characterized failure mode. Groups were compared using one‐way ANOVA or Kruskal‐Wallis tests. Significance was p < .05.
Results
Non‐destructive testing showed unilateral and bilateral APJ constructs were stiffer in flexion‐extension, axial rotation and lateral bending than non‐stabilized ( p < .05). In destructive testing, bilateral APJ stabilization was 2.5× stiffer than VCS, with similar failure moments. Construct stiffness was higher with bilateral APJ stabilization (27.89 ± 5.11 Nm/°) versus non‐stabilized (6.92 ± 3.90 Nm/°, p = .0037), unilateral APJ (14.06 ± 2.94 Nm/°, p < .0001) and VCS (11.28 ± 3.01 Nm/°, p < .0001) groups. Failure typically occurred as cranial articular process fracture in both bilateral and unilateral APJ constructs.
Conclusion
Bilateral APJ stabilization demonstrated greater stiffness than VCS with comparable failure moments. Clinical significance Bilateral APJ stabilization, with its higher stiffness than VCS, may be an alternative strategy to achieve spinal fusion in horses while avoiding a ventral surgical approach. Future investigations and development of this technique in vivo are warranted before implementation in clinical cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Colorado State University, College of Veterinary Medicine and Biomedical Sciences, Fort Collins, Colorado, USA.
- Orthopedic Bioengineering Research Laboratory, Colorado State University, Fort Collins, Colorado, USA.
ORCID-Profile: Machiel P Ysebaert, Donovan M David, Andres F Bonilla, Jeremiah T Easley, Brad B Nelson
Förderung
- American College of Veterinary Surgeons Foundation
Zitieren
APA
Ysebaert, M. P., Foslien, R., David, D. M., Bonilla, A. F., Gadomski, B. C., Easley, J. T., & Nelson, B. B. (2026). Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study. Veterinary Surgery, 55(8), 1340-1353. https://doi.org/10.1111/vsu.70166
Vancouver
Ysebaert MP, Foslien R, David DM, Bonilla AF, Gadomski BC, Easley JT, et al. Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study. Veterinary Surgery. 2026;55(8):1340-1353. doi:10.1111/vsu.70166
BibTeX
@article{Ysebaert2026,
author = {Ysebaert, Machiel P and Foslien, Ryan and David, Donovan M and Bonilla, Andres F and Gadomski, Ben C and Easley, Jeremiah T and Nelson, Brad B},
title = {Cervical articular process joint versus ventral cervical stabilization in horses: A biomechanical study},
journal = {Veterinary Surgery},
year = {2026},
volume = {55},
number = {8},
pages = {1340--1353},
doi = {10.1111/vsu.70166}
}
EUVIMED