EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Comparative biomechanical analysis of equine accessory carpal bone fracture repair: Cortical screws in lag fashion versus X‐plate technique

Jennifer Gernhardt iD, Thomas Reuter, Kathrin Mählmann iD, Nicole Schulze, Christoph J Lischer

Veterinary Surgery · 2025

DOI: 10.1111/vsu.70071 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Veterinary Surgery, 2025. Verfasst von Jennifer Gernhardt und 4 weiteren Autor:innen. Beteiligte Einrichtung: Equine Clinic, Freie Universität Berlin, Berlin, Germany. Hauptthemen laut MEDLINE: Bone Screws, Fractures, Bone, Fracture Fixation, Internal, Bone Plates. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DePuy Synthes.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the feasibility and biomechanical stability of two surgical techniques for fixation of vertical plane fractures of the accessory carpal bone (ACB). Study design Randomized experimental ex vivo study. Sample population Eight equine accessory carpal bones were included in a control group. A total of 20 equine cadaveric forelimbs were randomly assigned into two groups ( n = 10 per group).

Methods

Vertical plane fractures were created palmar to the extensor sulcus using an oscillating saw. In Group 1 (CS), fractures were stabilized with two 4.5 mm cortical screws in lag fashion. In Group 2 (XP), fixation included one 4.5 mm cortical screw in lag fashion and a laterally applied angular stable X‐plate with four 2.7 mm locking screws. Control ACBs were excised and tested under axial compression using a four‐column testing machine. Postoperative specimens in Groups CS and XP were tested under the same conditions. The failure mode was assessed radiographically.

Results

The mean maximum strength of native bone was 11.26 (±2.14) kN. Two constructs per group were excluded due to cortical screw protrusion. No difference in failure load was observed (CS: 6.82 [±2.34] kN; XP: 8.02 [±1.10] kN; p = .7558). Failure mode analysis revealed a greater fracture gap size ( p = .0039) and implant bending in CS specimens ( p = 1.074e‐7).

Conclusion

Both techniques were feasible, though neither restored native bone strength. Clinical significance A lateral X‐plate with a single cortical screw demonstrated equivalent biomechanical performance to two cortical screws and was technically less demanding, offering a simpler fixation option for ACB fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone ScrewsFractures, BoneFracture Fixation, InternalBone PlatesCarpal BonesAnimalsHorsesBiomechanical PhenomenaCadaver

Autor:innen und Institutionen

  • Equine Clinic, Freie Universität Berlin, Berlin, Germany.
  • ICM-Institut Chemnitzer Maschinen- und Anlagenbau e.V, Chemnitz, Germany.

ORCID-Profile: Jennifer Gernhardt, Kathrin Mählmann

Förderung

  • DePuy Synthes

Zitieren

APA

Gernhardt, J., Reuter, T., Mählmann, K., Schulze, N., & Lischer, C. J. (2025). Comparative biomechanical analysis of equine accessory carpal bone fracture repair: Cortical screws in lag fashion versus X‐plate technique. Veterinary Surgery. https://doi.org/10.1111/vsu.70071

Vancouver

Gernhardt J, Reuter T, Mählmann K, Schulze N, Lischer CJ. Comparative biomechanical analysis of equine accessory carpal bone fracture repair: Cortical screws in lag fashion versus X‐plate technique. Veterinary Surgery. 2025. doi:10.1111/vsu.70071

BibTeX
@article{Gernhardt2025,
  author = {Gernhardt, Jennifer and Reuter, Thomas and Mählmann, Kathrin and Schulze, Nicole and Lischer, Christoph J},
  title = {Comparative biomechanical analysis of equine accessory carpal bone fracture repair: Cortical screws in lag fashion versus X‐plate technique},
  journal = {Veterinary Surgery},
  year = {2025},
  doi = {10.1111/vsu.70071}
}
Kostenlos starten →