EUVIMEDEUVIMED entdecken
Crossref

Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study

Anderson F de Souza iD, César A M Pereira, Claudio Costa, Anton Fürst, Jan M Kümmerle, André L V De Zoppa

Veterinary and Comparative Orthopaedics and Traumatology · 2024-11 · 37 (06) · 263-272

DOI: 10.1055/s-0044-1787680 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, online erschienen am 04.06.2024. Verfasst von Anderson F de Souza und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil. Hauptthemen laut MEDLINE: Arthrodesis, Bone Screws, Bone Plates, Cadaver. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The aim of this study was to measure the mechanical properties and failure mode of an ex vivo model of proximal interphalangeal arthrodesis in horses with different methods of proximal screw fixation using a locking compression plate. Study Design Pastern joint arthrodesis with a 3-hole 4.5-mm narrow locking compression plate was performed on 20 forelimbs of equine cadavers, randomized into four groups based on the fixation method and type of proximal screw used: unicortical cortex, bicortical cortex, unicortical locking, bicortical locking. Single-cycle axial compression testing was conducted until failure. The frequency of implant plastic deformation was recorded. Bone failure analysis was performed through computed tomography examinations and fractal analysis.

Results

There were no differences in the analysed mechanical variables and fractal dimension among the groups. Transarticular screws showed a higher frequency of deformation (75%) regardless of the group. Both unicortical locking and bicortical locking groups deformed the plate more frequently.

Conclusion

The type of screw used in the proximal hole of the locking compression plate and its method of anchoring in the proximal phalanx do not affect the mechanical properties of pastern arthrodesis in equine cadavers subjected to single-cycle axial compression tests until failure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArthrodesisBone ScrewsBone PlatesCadaverAnimalsHorsesBiomechanical PhenomenaForelimb

Autor:innen und Institutionen

  • Department of Surgery, School of Veterinary Medicine and Animal Science, University of São Paulo, São Paulo, Brazil.
  • Institute de Orthopedics and Traumatology, School of Medicine, University of São Paulo, São Paulo, Brazil.
  • Department of Stomatology, School of Dentistry, University of São Paulo, São Paulo, Brazil.
  • Equine Department, Vetsuisse Faculty, University of Zurich, Zurich, Switzerland.

ORCID-Profile: Anderson F de Souza

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
  • Fundação de Amparo à Pesquisa do Estado de São Paulo

Zitieren

APA

de Souza, A. F., Pereira, C. A. M., Costa, C., Fürst, A., Kümmerle, J. M., & De Zoppa, A. L. V. (2024). Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study. Veterinary and Comparative Orthopaedics and Traumatology, 37(06), 263-272. https://doi.org/10.1055/s-0044-1787680

Vancouver

de Souza AF, Pereira CAM, Costa C, Fürst A, Kümmerle JM, De Zoppa ALV. Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study. Veterinary and Comparative Orthopaedics and Traumatology. 2024;37(06):263-272. doi:10.1055/s-0044-1787680

BibTeX
@article{deSouza2024,
  author = {de Souza, Anderson F and Pereira, César A M and Costa, Claudio and Fürst, Anton and Kümmerle, Jan M and De Zoppa, André L V},
  title = {Mechanical Properties and Failure Mode of Proximal Screw Fixation Technique Using Locking Compression Plate for Proximal Interphalangeal Arthrodesis in Horses: An Ex Vivo Study},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2024},
  volume = {37},
  number = {06},
  pages = {263--272},
  doi = {10.1055/s-0044-1787680}
}
Kostenlos starten →