3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study
Veterinary Surgery · 2026
DOI: 10.1111/vsu.70085 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Emma Aimonetti und 3 weiteren Autor:innen. Beteiligte Einrichtung: Clinique Vétérinaire de Grosbois, Boissy St. Léger, France. Hauptthemen laut MEDLINE: Arthrodesis, Printing, Three-Dimensional, Toe Joint. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Objective
To determine the benefit of using a three‐dimensional (3D)‐printed titanium aiming device for placing two 5.5‐mm transarticular screws during proximal interphalangeal joint (PIPJ) arthrodesis in equine species. Study design Ex vivo study. Sample population A total of 40 cadaveric forelimbs from adult horses.
Methods
A senior surgeon and a first‐year resident each performed 20 constructs: 10 using the device and 10 using a freehand technique. Procedure duration and number of intraoperative radiographs were recorded. Final radiographs were evaluated by an ECVS‐certified surgeon unaware of treatment group, based on two criteria: compliance with the AO principles, and symmetry and homogeneity of the construct. Following implants removal, the position of the thread hole on the articular surface of the second phalanx was assessed and graded for accuracy.
Results
For the inexperienced surgeon, the device reduced mean procedure time from 27.24 to 20.16 min (−25%, p < .01), decreased mean radiograph number from 6.1 to 2.1 (−60%, p < .01), and improved mean accuracy scores from 4.4 to 5.8 (+31%, p < .01). Construct symmetry also improved from 1.5 to 2.2 (+47%, p < .05). For the senior surgeon, only the number of radiographs was significantly reduced, from 3.1 to 1.3 (−58%, p < .01), with no significant difference in duration, accuracy, or symmetry.
Conclusion
The aiming device improved feasibility, accuracy, and repeatability of transarticular screw placement for the inexperienced surgeon. Impact This 3D‐printed device appears to be as a promising tool for achieving gold‐standard transarticular screw placement and may increases the accuracy of this surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Clinique Vétérinaire de Grosbois, Boissy St. Léger, France.
- Equine Clinic, Freie University, Berlin, Germany.
Zitieren
APA
Aimonetti, E., Genton, M., Lischer, C. J., & Rossignol, F. (2026). 3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study. Veterinary Surgery. https://doi.org/10.1111/vsu.70085
Vancouver
Aimonetti E, Genton M, Lischer CJ, Rossignol F. 3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study. Veterinary Surgery. 2026. doi:10.1111/vsu.70085
BibTeX
@article{Aimonetti2026,
author = {Aimonetti, Emma and Genton, Martin and Lischer, Christoph Johannes and Rossignol, Fabrice},
title = {3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study},
journal = {Veterinary Surgery},
year = {2026},
doi = {10.1111/vsu.70085}
}
EUVIMED