3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study

Emma Aimonetti, Martin Genton, Christoph Johannes Lischer, Fabrice Rossignol

Veterinary Surgery · 2026

DOI: 10.1111/vsu.70085 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Surgery, 2026. Verfasst von Emma Aimonetti und 3 weiteren Autor:innen. Beteiligte Einrichtung: Clinique Vétérinaire de Grosbois, Boissy St. Léger, France. Hauptthemen laut MEDLINE: Arthrodesis, Printing, Three-Dimensional, Toe Joint. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine the benefit of using a three‐dimensional (3D)‐printed titanium aiming device for placing two 5.5‐mm transarticular screws during proximal interphalangeal joint (PIPJ) arthrodesis in equine species. Study design Ex vivo study. Sample population A total of 40 cadaveric forelimbs from adult horses.

Methods

A senior surgeon and a first‐year resident each performed 20 constructs: 10 using the device and 10 using a freehand technique. Procedure duration and number of intraoperative radiographs were recorded. Final radiographs were evaluated by an ECVS‐certified surgeon unaware of treatment group, based on two criteria: compliance with the AO principles, and symmetry and homogeneity of the construct. Following implants removal, the position of the thread hole on the articular surface of the second phalanx was assessed and graded for accuracy.

Results

For the inexperienced surgeon, the device reduced mean procedure time from 27.24 to 20.16 min (−25%, p < .01), decreased mean radiograph number from 6.1 to 2.1 (−60%, p < .01), and improved mean accuracy scores from 4.4 to 5.8 (+31%, p < .01). Construct symmetry also improved from 1.5 to 2.2 (+47%, p < .05). For the senior surgeon, only the number of radiographs was significantly reduced, from 3.1 to 1.3 (−58%, p < .01), with no significant difference in duration, accuracy, or symmetry.

Conclusion

The aiming device improved feasibility, accuracy, and repeatability of transarticular screw placement for the inexperienced surgeon. Impact This 3D‐printed device appears to be as a promising tool for achieving gold‐standard transarticular screw placement and may increases the accuracy of this surgery.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArthrodesisPrinting, Three-DimensionalToe JointAnimalsHorsesBone ScrewsCadaverForelimb

Autor:innen und Institutionen

  • Clinique Vétérinaire de Grosbois, Boissy St. Léger, France.
  • Equine Clinic, Freie University, Berlin, Germany.

Zitieren

APA

Aimonetti, E., Genton, M., Lischer, C. J., & Rossignol, F. (2026). 3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study. Veterinary Surgery. https://doi.org/10.1111/vsu.70085

Vancouver

Aimonetti E, Genton M, Lischer CJ, Rossignol F. 3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study. Veterinary Surgery. 2026. doi:10.1111/vsu.70085

BibTeX
@article{Aimonetti2026,
  author = {Aimonetti, Emma and Genton, Martin and Lischer, Christoph Johannes and Rossignol, Fabrice},
  title = {3D printed aiming device for equine proximal interphalangeal joint arthrodesis: Ex vivo study},
  journal = {Veterinary Surgery},
  year = {2026},
  doi = {10.1111/vsu.70085}
}
Kostenlos starten →