Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement – a biomechanical human cadaveric study
European Journal of Trauma and Emergency Surgery · 2026
DOI: 10.1007/s00068-026-03380-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Trauma and Emergency Surgery, 2026. Verfasst von Adrian Deichsel und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert- Schweitzer-Campus 1, 48149, Münster, Germany. adrian.deic…. Hauptthemen laut MEDLINE: Bone Plates, Fracture Fixation, Internal, Patella Fracture, Bone Wires. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Münster.
Abstract (Originalsprache)
Purpose
To investigate whether the addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures provides improved biomechanical construct stability and reduced interfragmentary displacement.
Methods
A distal patellar pole fracture was simulated in sixteen fresh-frozen human cadaveric knees by a horizontal osteotomy in the distal third of the patella. Subsequently, locking plate fixation was performed. In a randomized half of the specimens, an additional McLaughlin wire cerclage was applied. The specimens were then subjected to 3000 cycles of extension starting at 90° of flexion under a maximum tensile load of 320 N. Using a Digital Image Correlation (DIC) system, the interfragmentary displacement between the proximal and distal fragments was measured at 1, 10, 20, 30, 50, 100, 500, 1000, 2000, and 3000 cycles. Statistical analysis was performed using repeated-measures ANOVA and Welch’s unpaired t -t test at 3000 cycles.
Results
An additional McLaughlin cerclage significantly reduced interfragmentary displacement under cyclic loading in comparison to locking plate fixation alone. After 3000 cycles, displacement was 2.27 ± 1.84 mm with plate fixation alone and 0.36 ± 0.22 mm with additional McLaughlin cerclage (mean difference 1.91 mm; 95% CI 0.38–3.45 mm; p = 0.0215).
Conclusion
An additional McLaughlin cerclage reduced interfragmentary displacement in distal patellar pole fractures. In cases of unstable distal pole patella fractures, the additional use of a McLaughlin cerclage may therefore be considered to enhance construct stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert- Schweitzer-Campus 1, 48149, Münster, Germany. adrian.deichsel@ukmuenster.de.
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Albert- Schweitzer-Campus 1, 48149, Münster, Germany.
- AO Research Institute Davos, Davos, Switzerland.
- Institute of Metal Science, Equipment and Technologies with Hydro- and Aerodynamics Centre "Acad. A. Balevski", Bulgarian Academy of Sciences, Sofia, Bulgaria.
Förderung
- Universitätsklinikum Münster
Zitieren
APA
Deichsel, A., Große-Allermann, A., Horst, K., Kittl, C., Lodde, M., Gueorguiev, B., Drenchev, L., Skulev, H. K., & Herbst, E. (2026). Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement – a biomechanical human cadaveric study. European Journal of Trauma and Emergency Surgery. https://doi.org/10.1007/s00068-026-03380-5
Vancouver
Deichsel A, Große-Allermann A, Horst K, Kittl C, Lodde M, Gueorguiev B, et al. Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement – a biomechanical human cadaveric study. European Journal of Trauma and Emergency Surgery. 2026. doi:10.1007/s00068-026-03380-5
BibTeX
@article{Deichsel2026,
author = {Deichsel, Adrian and Große-Allermann, Arian and Horst, Klemens and Kittl, Christoph and Lodde, Moritz and Gueorguiev, Boyko and Drenchev, Ludmil and Skulev, Hristo K and Herbst, Elmar},
title = {Addition of a McLaughlin cerclage to locking plate fixation of distal patellar pole fractures reduces interfragmentary displacement – a biomechanical human cadaveric study},
journal = {European Journal of Trauma and Emergency Surgery},
year = {2026},
doi = {10.1007/s00068-026-03380-5}
}
EUVIMED