The effect of an aiming device on the accuracy of humeral transcondylar screw placement
Veterinary Surgery · 2023
DOI: 10.1111/vsu.13952 ↗Kurz gefasst
Fachartikel in der Zeitschrift Veterinary Surgery, 2023. Verfasst von Katherine M Neal und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Sciences in Veterinary Medicine, Mississippi State University, Starkvilln, Mississippi, USA. Hauptthemen laut MEDLINE: Bone Screws, Spinal Fusion. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: College of Veterinary Medicine, Mississippi State University.
Abstract (Originalsprache)
Objectives
(1) To evaluate the accuracy of an aiming device on placement of humeral transcondylar screws compared to fluoroscopic methods. (2) To compare experience level on outcome. Study design Randomized, match pair, prospective ex‐vivo study. Sample population A total of 68 dogs.
Methods
Canine cadaveric forelimbs were randomly assigned to either aiming device or fluoroscopic‐guided groups, and to diplomate or resident. Digital radiography was used to evaluate screw trajectory deviation and eccentricity on the humeral condyle. Procedure time, outcome based on experience, and complications were recorded.
Results
The aiming device screw trajectory angle was decreased in the right limb (1.9 ± 1.1°) compared with the left (3.6 ± 1.1°, p = .0178), and compared to fluoroscopy (3.4 ± 1.1° p = .0128). There was no difference between leg laterality with fluoroscopy ( p = .9979). Trajectory angle was increased with resident versus diplomate (3.4 ± 1.1° and 2.5 ± 1.1° respectively, p = .0366). Eccentricity deviation was decreased using fluoroscopy versus aiming device (3.1 ± 0.36 mm, 4.2 ± 0.36 mm, respectively, p = .0017). The risk of joint involvement was 8 times greater in aiming device groups, though not significant ( p = .0575). Significant complications included increased drill attempts in fluoroscopic groups ( p = .0237).
Conclusion
The aiming device provided accurate placement of transcondylar screws, in terms of both position on the condyle and trajectory angle. Results were similar to fluoroscopic‐guided method. Clinical significance An aiming device is an acceptable means of placing humeral transcondylar screws. The use of the aiming device had an eight times increased risk of joint involvement compared to fluoroscopy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Clinical Sciences in Veterinary Medicine, Mississippi State University, Starkvilln, Mississippi, USA.
- Michigan State University, East Lansing, Michigan, USA.
- Department of Comparative Biomedical Sciences, Mississippi State University, Starkvilln, Mississippi, USA.
ORCID-Profile: Katherine M Neal
Förderung
- College of Veterinary Medicine, Mississippi State University
Zitieren
APA
Neal, K. M., Gallaher, H. M., Thompson, A., & Kerby, M. D. (2023). The effect of an aiming device on the accuracy of humeral transcondylar screw placement. Veterinary Surgery. https://doi.org/10.1111/vsu.13952
Vancouver
Neal KM, Gallaher HM, Thompson A, Kerby MD. The effect of an aiming device on the accuracy of humeral transcondylar screw placement. Veterinary Surgery. 2023. doi:10.1111/vsu.13952
BibTeX
@article{Neal2023,
author = {Neal, Katherine M and Gallaher, Hayley M and Thompson, Alexis and Kerby, Mary D},
title = {The effect of an aiming device on the accuracy of humeral transcondylar screw placement},
journal = {Veterinary Surgery},
year = {2023},
doi = {10.1111/vsu.13952}
}
EUVIMED