EUVIMEDEUVIMED entdecken
Crossref

Patient-specific Guides Improve the Accuracy and Safety of Transcondylar Screw Placement—A Cadaveric Study in the Canine Humerus

Joshua T Kershaw, Bill Oxley, Matthew J Allen iD

Veterinary and Comparative Orthopaedics and Traumatology · 01.09.2025 · 38 (05) · 214-220

DOI: 10.1055/a-2510-3720 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary and Comparative Orthopaedics and Traumatology, erschienen am 01.09.2025. Verfasst von Joshua T Kershaw und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine, Surgical Discovery Centre, University of Cambridge, Cambridge, United Kingdom. Hauptthemen laut MEDLINE: Bone Screws, Humerus, Fracture Fixation, Internal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The goal of this study was to compare the accuracy and safety of a transcondylar screw (TCS) placed using a 3D-printed patient-specific guide (PSG) or a generic aiming device (AD). We hypothesized that PSG is more accurate (i.e., positioning and orientation closer to the optimal trajectory) and safer (reduced incidence of joint violation) than the AD. A total of seven pairs of forelimbs were allocated to PSG and AD groups. After CT scanning, the optimal TCS orientation was planned in silico by a surgical specialist, and guides were printed. Using the PSG or AD, a 2.5-mm drill hole was drilled from medial to lateral across the humeral condyle. The positioning of the “planned” and “achieved” drill holes was defined on postoperative CT. The accuracy of TCS positioning and the risk of joint penetration were then calculated for the two groups. Positioning of the entry and exit holes was significantly more accurate in the PSG group. Differences in screw angulation were not significantly different between groups. Despite the presence of an outlier (caused by incomplete seating of the PSG against the bone), 7 out of 7 screws positioned with PSG were “safe,” while 3 out of 7 from the AD group would have violated the joint. Our data confirm the technical superiority of PSG over the AD for placement of a TCS in the humeral condyle.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Bone ScrewsHumerusFracture Fixation, InternalDogsAnimalsCadaverPrinting, Three-DimensionalTomography, X-Ray Computed

Autor:innen und Institutionen

  • Department of Veterinary Medicine, Surgical Discovery Centre, University of Cambridge, Cambridge, United Kingdom.
  • Vet3D, Kendall, United Kingdom.

ORCID-Profile: Matthew J Allen

Zitieren

APA

Kershaw, J. T., Oxley, B., & Allen, M. J. (2025). Patient-specific Guides Improve the Accuracy and Safety of Transcondylar Screw Placement—A Cadaveric Study in the Canine Humerus. Veterinary and Comparative Orthopaedics and Traumatology, 38(05), 214-220. https://doi.org/10.1055/a-2510-3720

Vancouver

Kershaw JT, Oxley B, Allen MJ. Patient-specific Guides Improve the Accuracy and Safety of Transcondylar Screw Placement—A Cadaveric Study in the Canine Humerus. Veterinary and Comparative Orthopaedics and Traumatology. 2025;38(05):214-220. doi:10.1055/a-2510-3720

BibTeX
@article{Kershaw2025,
  author = {Kershaw, Joshua T and Oxley, Bill and Allen, Matthew J},
  title = {Patient-specific Guides Improve the Accuracy and Safety of Transcondylar Screw Placement—A Cadaveric Study in the Canine Humerus},
  journal = {Veterinary and Comparative Orthopaedics and Traumatology},
  year = {2025},
  volume = {38},
  number = {05},
  pages = {214--220},
  doi = {10.1055/a-2510-3720}
}
Kostenlos starten →