Accuracy of screw placement during vertebral body tethering using fluoroscopic guidance and anatomic landmarks
Spine Deformity · 2025-01 · 13 (1) · 153-158
DOI: 10.1007/s43390-024-00970-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Spine Deformity, online erschienen am 18.09.2024. Verfasst von Kevin M Neal und 2 weiteren Autor:innen. Beteiligte Einrichtung: Orthopaedics Department, Nemours Children's Health, Jacksonville, FL, USA. Hauptthemen laut MEDLINE: Spinal Fusion, Bone Screws, Anatomic Landmarks, Thoracic Vertebrae. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
To determine the accuracy of screw placement using fluoroscopy and anatomic landmarks during vertebral body tethering (VBT) surgery.
Methods
Ten patients with 73 VBT screws were converted to posterior spinal fusion (PSF) after continued curve progression. The positions of each VBT screw were analyzed using intraoperative computed tomography (CT) scans performed for image guidance during VBT. Differences for screws placed using an open versus thoracoscopic approach were noted for the screw position in each vertebra, distance from the spinal canal, unicortical versus bicortical placement, the distance of screw tips from the thoracic aorta, and impingement of screws on adjacent rib heads.
Results
Seventy three (73) screws in ten (10) patients were available for analysis. Only 21% of screws were placed traversing the middle one-third of the vertebral body, without spinal canal penetration, with the distal tip placed unicortically or bicortically as planned, and without touching the thoracic aorta. The rates of non-ideal screw placement were not significantly different for screws placed via thoracoscopic versus open approaches. Five (5) screws (6.8%) penetrated the spinal canal 1–2 mm, but without known clinical sequelae.
Conclusion
The majority of VBT screws available for analysis were placed in non-ideal positions, suggesting that accurate screw placement using intraoperative fluoroscopy and anatomic landmarks can be challenging, but without adverse clinical consequences.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Orthopaedics Department, Nemours Children's Health, Jacksonville, FL, USA.
- Florida State University College of Medicine, Tallahassee, FL, USA.
- Orthopaedics Department, Nemours Children's Health, Orlando, FL, USA. Mona.mathew@nemours.org.
ORCID-Profile: Kevin M Neal, Kylie Krombholz, Mona Doshi
Zitieren
APA
Neal, K. M., Krombholz, K., & Doshi, M. (2025). Accuracy of screw placement during vertebral body tethering using fluoroscopic guidance and anatomic landmarks. Spine Deformity, 13(1), 153-158. https://doi.org/10.1007/s43390-024-00970-4
Vancouver
Neal KM, Krombholz K, Doshi M. Accuracy of screw placement during vertebral body tethering using fluoroscopic guidance and anatomic landmarks. Spine Deformity. 2025;13(1):153-158. doi:10.1007/s43390-024-00970-4
BibTeX
@article{Neal2025,
author = {Neal, Kevin M and Krombholz, Kylie and Doshi, Mona},
title = {Accuracy of screw placement during vertebral body tethering using fluoroscopic guidance and anatomic landmarks},
journal = {Spine Deformity},
year = {2025},
volume = {13},
number = {1},
pages = {153--158},
doi = {10.1007/s43390-024-00970-4}
}
EUVIMED