Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats

Mehmet Nur Çetin iD, Yusuf Sinan Şirin iD, Doğukan Polat, Batuhan Neyse iD, Latif Emrah Yanmaz

Veterinary Ophthalmology · 2027-01 · 30 (1)

DOI: 10.1111/vop.70304 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Ophthalmology, online erschienen am 18.11.2026. Verfasst von Mehmet Nur Çetin und 4 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Veterinary Medicine, Department of Surgery, Burdur Mehmet Akif Ersoy University, Burdur, Turkey. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rebound tonometry is widely used for measuring intraocular pressure (IOP) in cats; however, differences in clinical tonometer measurement configuration may contribute to variability in recorded values. This prospective repeated‐measures study compared IOP measurements obtained using horizontal and vertical Tonovet Plus clinical measurement configurations in 32 client‐owned, systemically and ophthalmologically normal conscious cats. Intraocular pressure was measured in the right eye while the probe was directed toward the center of the cornea and positioned 4–8 mm from the corneal surface. The order of horizontal and vertical configurations was randomized for each cat. Measurements were obtained by one experienced veterinary ophthalmologist and a trained student operator group. In the primary linear mixed‐effects analysis accounting for repeated measurements within cats, horizontal configuration was associated with an estimated 2.41‐mmHg higher IOP than vertical configuration ( β = 2.41 mmHg; 95% CI, 1.39–3.44; p < 0.001). The configuration‐associated difference was also observed separately for the experienced instructor (mean difference, 2.81 mmHg; 95% CI, 1.91–3.71; p < 0.001) and across the trained student operator group (2.00 mmHg; 95% CI, 0.81–3.19; p = 0.002). These findings indicate that horizontal and vertical Tonovet Plus clinical measurement configurations may yield different IOP values in conscious cats. As configuration changes may affect instrument handling, restraint, head positioning, and animal responses, the difference cannot be attributed solely to tonometer orientation or mechanics. Consistent configuration is therefore recommended when comparing serial IOP measurements in cats. Further controlled studies are needed to distinguish mechanical, ergonomic, and other examination‐related mechanisms.

Schlagwörter

Stichwörter der Autor:innen

catclinical measurement configurationintraocular pressurerebound tonometrystandardization

Autor:innen und Institutionen

  • Faculty of Veterinary Medicine, Department of Surgery, Burdur Mehmet Akif Ersoy University, Burdur, Turkey.
  • Cerrahpasa Veterinary Faculty Institute of Health Sciences, Istanbul University, Istanbul, Turkey.

ORCID-Profile: Mehmet Nur Çetin, Yusuf Sinan Şirin, Batuhan Neyse

Zitieren

APA

Çetin, M. N., Şirin, Y. S., Polat, D., Neyse, B., & Yanmaz, L. E. (2027). Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats. Veterinary Ophthalmology, 30(1). https://doi.org/10.1111/vop.70304

Vancouver

Çetin MN, Şirin YS, Polat D, Neyse B, Yanmaz LE. Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats. Veterinary Ophthalmology. 2027;30(1). doi:10.1111/vop.70304

BibTeX
@article{etin2027,
  author = {Çetin, Mehmet Nur and Şirin, Yusuf Sinan and Polat, Doğukan and Neyse, Batuhan and Yanmaz, Latif Emrah},
  title = {Comparison of Horizontal and Vertical Tonovet Plus Clinical Measurement Configurations for Intraocular Pressure Assessment in Conscious Cats},
  journal = {Veterinary Ophthalmology},
  year = {2027},
  volume = {30},
  number = {1},
  doi = {10.1111/vop.70304}
}
Kostenlos starten →