Effect of Order of Testing on Intraocular Pressure and Tear Production Measurement in Dogs

Kate Rowatt Keenen iD, Daniel Keenen iD, Elizabeth Adkins

Veterinary Ophthalmology · 2026-11 · 29 (6)

DOI: 10.1111/vop.70264 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Ophthalmology, online erschienen am 10.09.2026. Verfasst von Kate Rowatt Keenen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Hope Advanced Ophthalmology, Vienna, Virginia, USA. Hauptthemen laut MEDLINE: Intraocular Pressure, Tears, Tonometry, Ocular. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To determine if the order of performing Schirmer tear test −1 (STT‐1) and intraocular pressure (IOP) using a rebound tonometer influences the diagnostic values in a general population of dogs. Animals Studied 122 eyes from 61 dogs of a variety of signalments and presentations. Procedures Dogs were randomly assigned into IOP first (Group A) and STT‐1 first (Group B) groups. Each group had an STT‐1 test, IOP measured by rebound tonometry, fluorescein staining, and a complete ocular examination.

Results

No significant differences were found between Group A and Group B for either tear production ( p = 0.62) or IOP ( p = 0.27). There were no significant differences with gender for both groups, and no significant difference was found between left and right eyes for IOP when left eyes were measured first.

Conclusions

The order of performing STT‐1 and rebound tonometry has no significant effect on tear production or IOP for a general population of dogs. The order of testing is unlikely to have a clinically significant effect.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureTearsTonometry, OcularAnimalsDogsMaleFemale

Stichwörter der Autor:innen

KCSSchirmer tear test 1caninediagnostic testingglaucomarebound tonometry

Autor:innen und Institutionen

  • Hope Advanced Ophthalmology, Vienna, Virginia, USA.
  • Data Analysis Consultant, Sterling, Virginia, USA.

ORCID-Profile: Kate Rowatt Keenen, Daniel Keenen

Zitieren

APA

Keenen, K. R., Keenen, D., & Adkins, E. (2026). Effect of Order of Testing on Intraocular Pressure and Tear Production Measurement in Dogs. Veterinary Ophthalmology, 29(6). https://doi.org/10.1111/vop.70264

Vancouver

Keenen KR, Keenen D, Adkins E. Effect of Order of Testing on Intraocular Pressure and Tear Production Measurement in Dogs. Veterinary Ophthalmology. 2026;29(6). doi:10.1111/vop.70264

BibTeX
@article{Keenen2026,
  author = {Keenen, Kate Rowatt and Keenen, Daniel and Adkins, Elizabeth},
  title = {Effect of Order of Testing on Intraocular Pressure and Tear Production Measurement in Dogs},
  journal = {Veterinary Ophthalmology},
  year = {2026},
  volume = {29},
  number = {6},
  doi = {10.1111/vop.70264}
}
Kostenlos starten →