Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs
Journal of Veterinary Emergency and Critical Care · 2026-05 · 36 (3) · 324-329
DOI: 10.1111/vec.70101 ↗At a glance
Vergleichsstudie in Journal of Veterinary Emergency and Critical Care, published online on 2026-04-24. Written by Brandi E Lauer and 3 co-authors. Institution: Emergency and Critical Care Service, Angell Animal Medical Center, Boston, Massachusetts, USA. Major MEDLINE topics: Dogs, Body Temperature, Esophagus, Thermometers. 43 references. The full text is freely available in PubMed Central.
Abstract (original language)
Objective
To compare the accuracy of an intranasal thermometer with an esophageal thermometer for obtaining core body temperature in anesthetized dogs.
Design
Prospective single‐center observational study.
Setting
Private referral veterinary hospital. Animals Seventy‐three dogs undergoing anesthesia for elective procedures.
Interventions
Body temperature was measured using an intranasal thermometer and an esophageal thermometer. Results obtained by the two methods were compared. Measurements and Main Results A linear mixed‐effects model showed a statistically significant difference between the two methods of measurement, with the intranasal method showing a mean temperature reading 0.2°C (0.3°F) lower than the esophageal method (95% confidence interval [CI]: 0.131–0.225, β = −0.27; p < 0.001). Covariates such as neuter status, body weight, age, or American Society of Anesthesiologists class did not influence temperature readings. A Bland–Altman plot showed a mean difference (bias) of −0.2°C (−0.3°F), with most differences falling within the limits of agreement (±1.3°C [±2°F]), emphasizing the clinically acceptable range of variation between the two methods. Post hoc analysis using a clinically acceptable margin of 0.5°C (0.9°F) showed that the intranasal method was clinically noninferior to the esophageal method, with a 95% CI showing a mean difference of 0.13°C–0.23°C (0.20°F–0.34°F). Equivalence testing confirmed that temperature differences between the two methods were within the clinical margin of ±0.5°C (±0.9°F).
Conclusions
Although intranasal temperature measurement underestimates core body temperature by 0.2°C (0.3°F) (95% CI: 0.131–0.225) compared with esophageal measurement, the difference is generally clinically insignificant. Given that esophageal temperature is indicative of core body temperature, intranasal temperature measurement appears to be another reasonable surrogate for core body temperature measurement in anesthetized dogs.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- Emergency and Critical Care Service, Angell Animal Medical Center, Boston, Massachusetts, USA.
Cite
APA
Lauer, B. E., Reader, R., Babyak, J., & Bracker, K. (2026). Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs. Journal of Veterinary Emergency and Critical Care, 36(3), 324-329. https://doi.org/10.1111/vec.70101
Vancouver
Lauer BE, Reader R, Babyak J, Bracker K. Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs. Journal of Veterinary Emergency and Critical Care. 2026;36(3):324-329. doi:10.1111/vec.70101
BibTeX
@article{Lauer2026,
author = {Lauer, Brandi E and Reader, Rebecca and Babyak, Jolene and Bracker, Kiko},
title = {Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2026},
volume = {36},
number = {3},
pages = {324--329},
doi = {10.1111/vec.70101}
}
EUVIMED