EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs

Brandi E Lauer, Rebecca Reader, Jolene Babyak, Kiko Bracker

Journal of Veterinary Emergency and Critical Care · 2026-05 · 36 (3) · 324-329

DOI: 10.1111/vec.70101 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Veterinary Emergency and Critical Care, online erschienen am 24.04.2026. Verfasst von Brandi E Lauer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Emergency and Critical Care Service, Angell Animal Medical Center, Boston, Massachusetts, USA. Hauptthemen laut MEDLINE: Dogs, Body Temperature, Esophagus, Thermometers. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To compare the accuracy of an intranasal thermometer with an esophageal thermometer for obtaining core body temperature in anesthetized dogs.

Design

Prospective single‐center observational study.

Setting

Private referral veterinary hospital. Animals Seventy‐three dogs undergoing anesthesia for elective procedures.

Interventions

Body temperature was measured using an intranasal thermometer and an esophageal thermometer. Results obtained by the two methods were compared. Measurements and Main Results A linear mixed‐effects model showed a statistically significant difference between the two methods of measurement, with the intranasal method showing a mean temperature reading 0.2°C (0.3°F) lower than the esophageal method (95% confidence interval [CI]: 0.131–0.225, β = −0.27; p < 0.001). Covariates such as neuter status, body weight, age, or American Society of Anesthesiologists class did not influence temperature readings. A Bland–Altman plot showed a mean difference (bias) of −0.2°C (−0.3°F), with most differences falling within the limits of agreement (±1.3°C [±2°F]), emphasizing the clinically acceptable range of variation between the two methods. Post hoc analysis using a clinically acceptable margin of 0.5°C (0.9°F) showed that the intranasal method was clinically noninferior to the esophageal method, with a 95% CI showing a mean difference of 0.13°C–0.23°C (0.20°F–0.34°F). Equivalence testing confirmed that temperature differences between the two methods were within the clinical margin of ±0.5°C (±0.9°F).

Conclusions

Although intranasal temperature measurement underestimates core body temperature by 0.2°C (0.3°F) (95% CI: 0.131–0.225) compared with esophageal measurement, the difference is generally clinically insignificant. Given that esophageal temperature is indicative of core body temperature, intranasal temperature measurement appears to be another reasonable surrogate for core body temperature measurement in anesthetized dogs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

DogsBody TemperatureEsophagusThermometersAnesthesiaMaleFemaleAnimalsProspective Studies

Stichwörter der Autor:innen

caninecore body temperaturegeneral anesthesianasal temperaturethermoregulation

Autor:innen und Institutionen

  • Emergency and Critical Care Service, Angell Animal Medical Center, Boston, Massachusetts, USA.

Zitieren

APA

Lauer, B. E., Reader, R., Babyak, J., & Bracker, K. (2026). Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs. Journal of Veterinary Emergency and Critical Care, 36(3), 324-329. https://doi.org/10.1111/vec.70101

Vancouver

Lauer BE, Reader R, Babyak J, Bracker K. Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs. Journal of Veterinary Emergency and Critical Care. 2026;36(3):324-329. doi:10.1111/vec.70101

BibTeX
@article{Lauer2026,
  author = {Lauer, Brandi E and Reader, Rebecca and Babyak, Jolene and Bracker, Kiko},
  title = {Comparison of Esophageal and Intranasal Temperature Measurement in Anesthetized Dogs},
  journal = {Journal of Veterinary Emergency and Critical Care},
  year = {2026},
  volume = {36},
  number = {3},
  pages = {324--329},
  doi = {10.1111/vec.70101}
}
Kostenlos starten →