The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs
Journal of Veterinary Emergency and Critical Care · 2024
DOI: 10.1111/vec.13426 ↗At a glance
Journal article in Journal of Veterinary Emergency and Critical Care, 2024. Written by Samantha K Day and 4 co-authors. Institution: School of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia. Major MEDLINE topics: Thrombelastography. Cited 1 times so far (Crossref); 40 references. The full text is freely available (open access, CC BY 4.0). Funded by: John and Mary Trust, Stone Memorial Fund Kibble Grant.
Abstract (original language)
Objective
To establish reference intervals using a new point‐of‐care thromboelastometry device in dogs for the extrinsically activated test (EX‐test), intrinsically activated test (IN‐test), fibrin polymerization test (FIB‐test), ecarin test (ECA‐test), and tissue plasminogen activator test (TPA‐test) and to investigate the effects of storage time on the results.
Design
Prospective clinical study in 2022.
Setting
University teaching hospital. Animals Forty‐eight healthy privately or university‐owned dogs were prospectively enrolled and included on the basis of normal physical examination and normal baseline laboratory results (CBC, biochemistry profile, prothrombin time, and activated partial thromboplastin time [aPTT]).
Interventions
After a 30‐minute storage time, the EX‐test, IN‐test, FIB‐test, ECA‐test, and TPA‐test were performed on citrated blood samples. To determine the effect of storage time, 11 samples had the EX‐test, FIB‐test, and IN‐test repeated 90 and 150 minutes after sample collection. Measurements and Main Results Ten thromboelastometry parameters were evaluated for each test. Reference intervals were calculated using the robust method for parametric data, and the robust Box–Cox transformed or nonparametric methods were used for nonparametric data. Increasing storage time resulted in more hypocoagulable tracings. A correlation was found between the IN‐test and aPTT ( r = 0.62, P < 0.0001). Other weak to moderate correlations were seen between thromboelastometry parameters and platelet count and hematocrit. Conclusions and Clinical Importance The development of reference intervals for the thromboelastometry device allows for the clinical use of this technology. Analyzing samples after a prolonged storage time of more than 30 minutes may result in erroneous results. Results may also be affected by an abnormal hematocrit or platelet count.
Subjects
MeSH terms (MEDLINE)
Author keywords
Authors and institutions
- School of Veterinary Science, The University of Queensland, Gatton, Queensland, Australia.
- School of Biomedical Sciences, The University of Queensland, Gatton, Queensland, Australia.
ORCID profiles: Samantha K Day, Sarah L Purcell
Funding
- John and Mary Trust
- Stone Memorial Fund Kibble Grant
Cite
APA
Day, S. K., Nash, K. J., Midwinter, M. J., Purcell, S. L., & Goodwin, W. A. (2024). The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs. Journal of Veterinary Emergency and Critical Care. https://doi.org/10.1111/vec.13426
Vancouver
Day SK, Nash KJ, Midwinter MJ, Purcell SL, Goodwin WA. The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs. Journal of Veterinary Emergency and Critical Care. 2024. doi:10.1111/vec.13426
BibTeX
@article{Day2024,
author = {Day, Samantha K and Nash, Katherine J and Midwinter, Mark J and Purcell, Sarah L and Goodwin, Wendy A},
title = {The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs},
journal = {Journal of Veterinary Emergency and Critical Care},
year = {2024},
doi = {10.1111/vec.13426}
}
EUVIMED