Whole blood storage time impairs clot strength with minimal change in functional fibrinogen concentration
Transfusion · 2026-05 · 66 (S1)
DOI: 10.1111/trf.70150 ↗At a glance
Journal article in Transfusion, published online on 2026-03-11. Written by Elizabeth R Maginot and 13 co-authors. Institution: Division of Acute Care Surgery, Department of Surgery, University of Nebraska Medical Center, Omaha, Nebraska, USA. Major MEDLINE topics: Blood Preservation, Fibrinogen, Blood Coagulation. 36 references. The full text is freely available in PubMed Central. Funded by: NHLBI NIH HHS, NIGMS NIH HHS, National Institute of General Medical Sciences.
Abstract (original language)
Background
Whole blood (WB) is a preferred resuscitation strategy, yet how storage affects hemostasis remains unclear. Prior studies have shown decreased fibrinogen function during storage; however, these were limited by incomplete removal of platelet contributions. Additionally, leukoreduced (LR) versus non‐leukoreduced (NLR) status in preserving fibrinogen remains unknown. Study Methods WB units ( n = 15, 7 NLR, 8 nLR) were evaluated at serial time points through day 35. ROTEM EXTEM was performed. Platelet‐poor plasma (PPP) from WB at day 0, day 21, and day 35 underwent western blot for fibrinogen. Functional fibrinogen was measured using the Clauss assay after freeze–thaw cycles of WB PPP to minimize platelet contribution.
Results
As WB aged, there was a progressive decrease in alpha angle and maximum clot firmness. Platelet count dropped sharply by day 7. Western blot demonstrated no evidence of fibrinogen degradation in either LR or NLR WB. Clauss fibrinogen concentrations were unchanged from day 0 to day 35, with a modest non‐significant decline by day 35 driven primarily by NLR units.
Discussion
Fibrinogen did not undergo detectable proteolysis during storage of WB and had preserved function through day 35 after freeze–thaw cycles to minimize platelet contributions. NLR appeared to impact fibrinogen function with medians below 200 for day 21 and 35 but was not statistically significant. This suggests that previously reported reductions in fibrinogen function may be based on leukoreduction status, but that early changes in fibrinolysis sensitivity are more likely due to residual platelet contributions to the assays rather than loss of fibrinogen function itself.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Division of Acute Care Surgery, Department of Surgery, University of Nebraska Medical Center, Omaha, Nebraska, USA.
- Department of Cellular and Integrative Physiology, University of Nebraska Medical Center, Omaha, Nebraska, USA.
- Department of Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
- Trauma and Transfusion Medicine Research Center, Department of Surgery, University of Pittsburgh, Pennsylvania, USA.
- Department of Pathology, Microbiology and Immunology, University of Nebraska Medical Center, Omaha, Nebraska, USA.
- Department of Surgery, Division of Trauma, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
ORCID profiles: Timothy R Billiar, Aleh Bobr, Susan M Shea, Christopher D Barrett
Funding
- NHLBI NIH HHS
- NIGMS NIH HHS
- National Institute of General Medical Sciences
- National Heart, Lung, and Blood Institute
Cite
APA
Maginot, E. R., Barmettler, N. K., Gawargi, F. I., White, C. M., Goodman, N., Billiar, T. R., Munitz, R., Koepsell, S. A., Williams, S. M., Bobr, A., Spinella, P. C., Shea, S. M., Henry, R., & Barrett, C. D. (2026). Whole blood storage time impairs clot strength with minimal change in functional fibrinogen concentration. Transfusion, 66(S1). https://doi.org/10.1111/trf.70150
Vancouver
Maginot ER, Barmettler NK, Gawargi FI, White CM, Goodman N, Billiar TR, et al. Whole blood storage time impairs clot strength with minimal change in functional fibrinogen concentration. Transfusion. 2026;66(S1). doi:10.1111/trf.70150
BibTeX
@article{Maginot2026,
author = {Maginot, Elizabeth R and Barmettler, Nicolle K and Gawargi, Flobater I and White, Collin M and Goodman, Natasha and Billiar, Timothy R and Munitz, Refael and Koepsell, Scott A and Williams, Shelly M and Bobr, Aleh and Spinella, Phillip C and Shea, Susan M and Henry, Reynold and Barrett, Christopher D},
title = {Whole blood storage time impairs clot strength with minimal change in functional fibrinogen concentration},
journal = {Transfusion},
year = {2026},
volume = {66},
number = {S1},
doi = {10.1111/trf.70150}
}
EUVIMED