Coagulation and platelet function in cold‐stored whole blood on missions in a helicopter emergency service
Acta Anaesthesiologica Scandinavica · 2025
DOI: 10.1111/aas.14568 ↗Kurz gefasst
Fachartikel in der Zeitschrift Acta Anaesthesiologica Scandinavica, 2025. Verfasst von José-Gabriel Sato Folatre und 7 weiteren Autor:innen. Beteiligte Einrichtung: Helicopter Emergency Medical Service, Region Västra Götaland, Kungälv, Sweden. Hauptthemen laut MEDLINE: Air Ambulances, Blood Coagulation, Blood Preservation, Blood Platelets. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Helicopter Emergency Medical Service, Region Västra Götaland, The Swedish Armed Forces Science & Technology Fund, The Centre for Disaster Medicine, Gothenburg University.
Abstract (Originalsprache)
Background
Haemorrhage is a leading cause of morbidity and mortality in trauma, and prehospital transfusion of blood products is often necessary. Whole blood has been proposed to be the best alternative, but it is unclear whether, and how, storage and transport of the blood in a helicopter affects the blood units. We investigated the coagulation capacity and platelet function in whole blood at different time points during helicopter missions.
Methods
Twenty units of low‐titre group O RhD negative whole blood were collected from healthy volunteers and analysed before, during and after transport in a helicopter. Coagulation and platelet function, as measured by thromboelastography, and blood samples for pH, electrolytes, glucose and lactate were assessed at baseline and 24, 72 and 168 h after storage in the helicopter. Plasma concentrations of coagulation factors and haemoglobin and blood counts were measured at baseline and after 168 h.
Results
Plasma concentrations of coagulation factors and haemoglobin did not change during storage and transport. Platelet counts decreased from a baseline mean of 172 ± 29 × 10 9 /L to a mean of 120 ± 28 × 10 9 /L after 168 h, and platelet function worsened slightly but significantly by 8%–9% during storage and transport. pH and glucose decreased while potassium and lactate levels increased after 168 h compared with baseline.
Conclusion
Storage and transport of whole‐blood units in a rescue helicopter, for up to 168 h, had a slight impact on the blood quality. Storage of whole blood on board of the helicopter holds up to European standard, measured as temperature and haemolysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Helicopter Emergency Medical Service, Region Västra Götaland, Kungälv, Sweden.
- Department of Anaesthesiology and Intensive Care, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.
- Centre for Haematology and Regenerative Medicine (HERM), Karolinska University Hospital, Stockholm, Sweden.
- Department of Clinical Science, Intervention and Technology (CLINTEC), Karolinska Institute, Stockholm, Sweden.
- Department of Haematology and Coagulation Disorders, Sahlgrenska University Hospital, Gothenburg, Sweden.
- Department of War Studies, Swedish Defence University, Stockholm, Sweden.
ORCID-Profile: José-Gabriel Sato Folatre, Agneta Wikman, Göran Sandström, Sven-Erik Ricksten, Birgitta Romlin
Förderung
- Helicopter Emergency Medical Service, Region Västra Götaland
- The Swedish Armed Forces Science & Technology Fund
- The Centre for Disaster Medicine, Gothenburg University
- The Department of Haematology and Coagulation Disorders
- The Local Research and Development Council Fyrbodal
- The Swedish Society for Military Medical Officers
Zitieren
APA
Sato Folatre, J. G., Wikman, A., Radulovic, V., Sandström, G., Skallsjö, G., Arnell, P., Ricksten, S. E., & Romlin, B. (2025). Coagulation and platelet function in cold‐stored whole blood on missions in a helicopter emergency service. Acta Anaesthesiologica Scandinavica. https://doi.org/10.1111/aas.14568
Vancouver
Sato Folatre JG, Wikman A, Radulovic V, Sandström G, Skallsjö G, Arnell P, et al. Coagulation and platelet function in cold‐stored whole blood on missions in a helicopter emergency service. Acta Anaesthesiologica Scandinavica. 2025. doi:10.1111/aas.14568
BibTeX
@article{SatoFolatre2025,
author = {Sato Folatre, José-Gabriel and Wikman, Agneta and Radulovic, Vladimir and Sandström, Göran and Skallsjö, Gabriel and Arnell, Per and Ricksten, Sven-Erik and Romlin, Birgitta},
title = {Coagulation and platelet function in cold‐stored whole blood on missions in a helicopter emergency service},
journal = {Acta Anaesthesiologica Scandinavica},
year = {2025},
doi = {10.1111/aas.14568}
}
EUVIMED