Simple image analysis for reliability control of column agglutination test in pretransfusion testing
Transfusion Medicine · 05.07.2026
DOI: 10.1111/tme.70103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Transfusion Medicine, online erschienen am 05.07.2026. Verfasst von Martin Töffner Pedersen und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Blood Tests, Biochemistry and Immunology, University Hospital of Southern Denmark, Aabenraa, Denmark. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Canada Excellence Research Chairs, Government of Canada.
Abstract (Originalsprache)
Objectives
A novel meniscus‐based analysis provides a rapid method to identify analytical errors related to unrecognised pipetting errors.
Background
The indirect antihuman globulin test (IAT) is part of pretransfusion testing, enabling detection of erythrocyte alloantibodies. Failure to detect such antibodies may result in transfusion complications. In column agglutination technique (CAT)‐based IAT, correct separation of the different liquids by an air gap during incubation is essential. Penetration of this air gap due to pipetting errors can cause neutralisation of AHG, resulting in false‐negative or weak test results. Materials and Methods We investigated the fluid dynamics of CAT‐based IAT and developed a simple image‐based quality control approach to detect air gap penetration. Using routinely generated analyser images, the meniscus contact angle was quantified with the software ImageJ in 132 simulated crossmatch tests.
Results
Receiver operating characteristic analysis demonstrated high discriminatory performance (AUC 0.935). Additional experiments using bovine serum albumin solutions confirmed that increased protein concentration significantly reduces meniscus contact angle, supporting the proposed mechanism of error prediction.
Conclusion
While further validation across platforms and laboratories is required, this approach has the potential to enhance test reliability, support troubleshooting, and improve patient safety in routine IAT CAT workflows.
Autor:innen und Institutionen
- Department of Blood Tests, Biochemistry and Immunology, University Hospital of Southern Denmark, Aabenraa, Denmark.
- Department of Engineering Physics, McMaster University, Hamilton, Canada.
- Department of Regional Health Research, University of Southern Denmark, Odense, Denmark.
ORCID-Profile: Martin Töffner Pedersen, Albert Ashong, Niko Hildebrandt
Förderung
- Canada Excellence Research Chairs, Government of Canada
Zitieren
APA
Pedersen, M. T., Rajaguru, T., Ashong, A., Arbi, R., Hildebrandt, N., & Skovsted, T. (2026). Simple image analysis for reliability control of column agglutination test in pretransfusion testing. Transfusion Medicine. https://doi.org/10.1111/tme.70103
Vancouver
Pedersen MT, Rajaguru T, Ashong A, Arbi R, Hildebrandt N, Skovsted T. Simple image analysis for reliability control of column agglutination test in pretransfusion testing. Transfusion Medicine. 2026. doi:10.1111/tme.70103
BibTeX
@article{Pedersen2026,
author = {Pedersen, Martin Töffner and Rajaguru, Tharisa and Ashong, Albert and Arbi, Ramis and Hildebrandt, Niko and Skovsted, Thor},
title = {Simple image analysis for reliability control of column agglutination test in pretransfusion testing},
journal = {Transfusion Medicine},
year = {2026},
doi = {10.1111/tme.70103}
}
EUVIMED