EUVIMEDEUVIMED entdecken
Crossref

Practice of ABO antibody titration in a transplant center: From tube method to manual gel column testing to automated column agglutination technology

Jun-Bo Sun iD, Li-Wen Chen, Li-Li Tao, Qing-Si Wu, Qian-Qian Yu, Zhi-Wei Xie

Transfusion Medicine · 2025-06 · 35 (3) · 258-265

DOI: 10.1111/tme.13127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Transfusion Medicine, online erschienen am 29.01.2025. Verfasst von Jun-Bo Sun und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Blood Transfusion, The Second Affiliated Hospital of Anhui Medical University, Hefei, China. Hauptthemen laut MEDLINE: ABO Blood-Group System, Blood Grouping and Crossmatching, Blood Group Incompatibility, Isoantibodies. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Anhui Province Graduate Education Quality Project, China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Objectives High‐quality ABO antibody titre testing is required for ABO‐incompatible haematopoietic stem cell transplantation and kidney transplantation. To assess the feasibility of automated ABO titration as an alternative to manual and semi‐automatic titration during the peri‐transplant period, a comparative study was conducted internally in a transfusion medicine laboratory. Materials and Methods This study was performed in two stages. Firstly, the differences in anti‐A/B detecting using conventional tube test (CTT) and manual column agglutination technology (CAT) were compared in group O pregnant women. Then, manual and automated CAT were applied to simultaneously detect ABO antibody levels in non‐AB‐group adult haematological oncology patients.

Results

In the first stage, four groups of 192 comparable results were generated from 48 subjects, which showed a high correlation between CTT and manual CAT ( p < 0.001). However, the detection sensitivity of the latter was at least 1 fold higher dilution than that of the former. Fifty‐six patients were tested in the second stage by simultaneous manual and automated CAT, and the paired titers differed within an acceptable range (±1 fold dilution). However, the concordance was slightly higher in group IgM (85.4%) than in group IgG (80.5%). Blood group specificity of ABO titers was also observed in this population, and no association between titers and other factors was found.

Conclusion

Automated CAT standardises ABO titre testing and saves labor costs, although manual review of weak positive reactions is still necessary. Due to the blood group specificity of ABO antibodies, special attention should be paid to the quality control and clinical relevance of titre testing for group O recipients in ABO‐mismatched transplantation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ABO Blood-Group SystemBlood Grouping and CrossmatchingBlood Group IncompatibilityIsoantibodiesHematopoietic Stem Cell TransplantationAgglutination TestsHumansFemaleAdultMiddle AgedMalePregnancyKidney TransplantationAged

Stichwörter der Autor:innen

ABO antibodyABO incompatibilityantibody titrationcolumn agglutination techniquetransplantation

Substanzen

ABO Blood-Group SystemIsoantibodies

Autor:innen und Institutionen

  • Department of Blood Transfusion, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
  • Department of Hematology, The Second Affiliated Hospital of Anhui Medical University, Hefei, China.
  • Department of Pediatrics (Hematology Ward), The Second Affiliated Hospital of Anhui Medical University, Hefei, China.

ORCID-Profile: Jun-Bo Sun

Förderung

  • Anhui Province Graduate Education Quality Project, China

Zitieren

APA

Sun, J. B., Chen, L. W., Tao, L. L., Wu, Q. S., Yu, Q. Q., & Xie, Z. W. (2025). Practice of ABO antibody titration in a transplant center: From tube method to manual gel column testing to automated column agglutination technology. Transfusion Medicine, 35(3), 258-265. https://doi.org/10.1111/tme.13127

Vancouver

Sun JB, Chen LW, Tao LL, Wu QS, Yu QQ, Xie ZW. Practice of ABO antibody titration in a transplant center: From tube method to manual gel column testing to automated column agglutination technology. Transfusion Medicine. 2025;35(3):258-265. doi:10.1111/tme.13127

BibTeX
@article{Sun2025,
  author = {Sun, Jun-Bo and Chen, Li-Wen and Tao, Li-Li and Wu, Qing-Si and Yu, Qian-Qian and Xie, Zhi-Wei},
  title = {Practice of ABO antibody titration in a transplant center: From tube method to manual gel column testing to automated column agglutination technology},
  journal = {Transfusion Medicine},
  year = {2025},
  volume = {35},
  number = {3},
  pages = {258--265},
  doi = {10.1111/tme.13127}
}
Kostenlos starten →