Long‐term test and retest reliability of clinical vergence testing
Ophthalmic and Physiological Optics · 2025-11 · 45 (7) · 1630-1641
DOI: 10.1111/opo.70022 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Ophthalmic and Physiological Optics, online erschienen am 06.10.2025. Verfasst von Mitchell Scheiman und 11 weiteren Autor:innen. Beteiligte Einrichtung: Pennsylvania College of Optometry at Salus at Drexel University, Elkins Park, Pennsylvania, USA. Hauptthemen laut MEDLINE: Convergence, Ocular, Vision, Binocular, Vision Tests. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS, Research to Prevent Blindness, NCATS NIH HHS.
Abstract (Originalsprache)
Purpose
To establish long‐term reliability measures for vergence testing in a control population of adolescents.
Methods
Healthy participants between 12 and 17.5 years with normal binocular vision were recruited from 10 clinical sites. Cover test, near point of convergence (NPC), positive and negative fusional vergences, vergence facility (12∆ base‐out/3∆ base‐in) and vergence jumps (using the Oculomotor Assessment Tool) were performed at the initial visit and repeated at 90 days. The mean and standard deviation were calculated for the overall group for NPC, vergence facility and vergence jumps and by prism dioptre step value for PFV and NFV (1Δ or 2Δ if below 20∆ or 5Δ above 20∆). Agreement was assessed using Bland–Altman plots and 95% limits of agreement (LOA).
Results
Ninety‐three participants (mean age 14.3 ± 1.7 years, 52% female) were enrolled and 91 (98%) completed the initial and 90‐day outcome evaluation. The mean differences were significantly greater than zero for vergence facility ( p < 0.05) and the first and second 30 s of vergence jumps ( p < 0.01). The 95% LOA were narrow for NPC (±2.5) and negative fusional vergence (±5.9), suggesting good repeatability. LOA were larger for positive fusional vergence (±17.8), vergence facility (±9.8) and vergence jumps (±16.2). Analysis of the positive fusional vergence data indicates that the different step sizes (1∆ or 2∆ vs. 5∆) in the horizontal prism bar contribute to considerably larger variability in these measures.
Conclusions
In participants with normal binocular vision and no concussion history, good reliability yielded comparable results 90 days apart for all vergence measures. The results provide values that can be used to interpret the effect of intervention for vergence disorders in clinical practice and research studies. An important outcome of this study is the understanding that 5∆ steps on the typical horizontal prism bar contribute to high variability in positive fusional vergence measures when findings are ≥20∆.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Pennsylvania College of Optometry at Salus at Drexel University, Elkins Park, Pennsylvania, USA.
- Boston Children's Hospital, Boston, Massachusetts, USA.
- Children's Hospital of Philadelphia, Philadelphia, Pennsylvania, USA.
- The Ohio State University College of Optometry, Columbus, Ohio, USA.
- Spencer Center for Vision Research, Byers Eye Institute at Stanford University, Stanford, California, USA.
ORCID-Profile: Mitchell Scheiman, Lisa A Jordan
Förderung
- NEI NIH HHS
- Research to Prevent Blindness
- NCATS NIH HHS
- National Center for Advancing Translational Sciences
- National Eye Institute
Zitieren
APA
Scheiman, M., Raghuram, A., Master, C., Robich, M. L., Toole, A., Shelton, E. R., Srinivasan, G., Marusic, S., Meiyeppen, S., Jordan, L. A., Roberts, T. L., & EPICC Study Group (2025). Long‐term test and retest reliability of clinical vergence testing. Ophthalmic and Physiological Optics, 45(7), 1630-1641. https://doi.org/10.1111/opo.70022
Vancouver
Scheiman M, Raghuram A, Master C, Robich ML, Toole A, Shelton ER, et al. Long‐term test and retest reliability of clinical vergence testing. Ophthalmic and Physiological Optics. 2025;45(7):1630-1641. doi:10.1111/opo.70022
BibTeX
@article{Scheiman2025,
author = {Scheiman, Mitchell and Raghuram, Aparna and Master, Christina and Robich, Matthew L and Toole, Andrew and Shelton, Erica R and Srinivasan, Gayathri and Marusic, Sophia and Meiyeppen, Siva and Jordan, Lisa A and Roberts, Tawna L and EPICC Study Group, EPICC Study Group},
title = {Long‐term test and retest reliability of clinical vergence testing},
journal = {Ophthalmic and Physiological Optics},
year = {2025},
volume = {45},
number = {7},
pages = {1630--1641},
doi = {10.1111/opo.70022}
}
EUVIMED