Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device
Skin Research and Technology · 2023
DOI: 10.1111/srt.13472 ↗Kurz gefasst
Fachartikel in der Zeitschrift Skin Research and Technology, 2023. Verfasst von Yiyou Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SJTU-ZJ BME Research Center.
Abstract (Originalsprache)
Background
Non‐ablative radiofrequency (RF) has been widely used in clinical and at‐home cosmetics devices. RF electrode geometry can influence the heat distribution in the tissue. This study analyzes the influence of geometric parameters of the electrode on the heat distribution in the layered tissue. Materials & methods The finite element simulation of the electrothermal coupling field was performed to obtain the three‐dimensional (3D) temperature distribution of the four‐layer tissue. The electrode geometric parameters including the inter‐electrode spacing (5‐12 mm), width (1‐3 mm), length (3‐10 mm), shapes (bar, dot and circle), and the coupling gel's electrical conductivity (0.2‐1.5 S/m) were simulated. The maximum temperature at 2 mm depth ( T ‐2 mm ) and the temperature difference ( T diff ) between the maximum skin surface temperature and T ‐2 mm were obtained to evaluate the effectiveness and safety.
Results
The effect of geometric parameters on the effectiveness and safety was mixed. The maximum T ‐2 mm occurred with the 5 mm inter‐electrode spacing, 3 mm width, 10 mm length, the circle‐shaped electrode, and the 1.5 S/m coupling gel's electrical conductivity. The ratio of inter‐electrode spacing to width at around four can achieve rapid temperature rise and skin surface temperature protection. The electrode shape influenced the area of temperature rise in the tissue's cross‐section. The coupling gel's electrical conductivity should be close to that of the skin to avoid energy accumulation on the skin surface.
Conclusion
The electrode's geometric parameters affect the effectiveness and safety of the RF product. This study has provided the simulation procedure for the electrode design.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
- Shenzhen Accompany Tech co., ltd, Shenzhen, China.
ORCID-Profile: Yiyou Ma
Förderung
- SJTU-ZJ BME Research Center
Zitieren
APA
Ma, Y., Wang, N., Li, K., Liang, H., Bai, J., & Ji, X. (2023). Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device. Skin Research and Technology. https://doi.org/10.1111/srt.13472
Vancouver
Ma Y, Wang N, Li K, Liang H, Bai J, Ji X. Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device. Skin Research and Technology. 2023. doi:10.1111/srt.13472
BibTeX
@article{Ma2023,
author = {Ma, Yiyou and Wang, Nianou and Li, Ke and Liang, Huan and Bai, Jingfeng and Ji, Xiang},
title = {Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device},
journal = {Skin Research and Technology},
year = {2023},
doi = {10.1111/srt.13472}
}
EUVIMED