EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device

Yiyou Ma iD, Nianou Wang, Ke Li, Huan Liang, Jingfeng Bai, Xiang Ji

Skin Research and Technology · 2023

DOI: 10.1111/srt.13472 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Skin Research and Technology, 2023. Verfasst von Yiyou Ma und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China. Hauptthemen laut MEDLINE: Catheter Ablation. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 55 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: SJTU-ZJ BME Research Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Non‐ablative radiofrequency (RF) has been widely used in clinical and at‐home cosmetics devices. RF electrode geometry can influence the heat distribution in the tissue. This study analyzes the influence of geometric parameters of the electrode on the heat distribution in the layered tissue. Materials & methods The finite element simulation of the electrothermal coupling field was performed to obtain the three‐dimensional (3D) temperature distribution of the four‐layer tissue. The electrode geometric parameters including the inter‐electrode spacing (5‐12 mm), width (1‐3 mm), length (3‐10 mm), shapes (bar, dot and circle), and the coupling gel's electrical conductivity (0.2‐1.5 S/m) were simulated. The maximum temperature at 2 mm depth ( T ‐2 mm ) and the temperature difference ( T diff ) between the maximum skin surface temperature and T ‐2 mm were obtained to evaluate the effectiveness and safety.

Results

The effect of geometric parameters on the effectiveness and safety was mixed. The maximum T ‐2 mm occurred with the 5 mm inter‐electrode spacing, 3 mm width, 10 mm length, the circle‐shaped electrode, and the 1.5 S/m coupling gel's electrical conductivity. The ratio of inter‐electrode spacing to width at around four can achieve rapid temperature rise and skin surface temperature protection. The electrode shape influenced the area of temperature rise in the tissue's cross‐section. The coupling gel's electrical conductivity should be close to that of the skin to avoid energy accumulation on the skin surface.

Conclusion

The electrode's geometric parameters affect the effectiveness and safety of the RF product. This study has provided the simulation procedure for the electrode design.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationHumansHeatingElectrodesTemperatureBody Temperature

Stichwörter der Autor:innen

electrode designelectrothermal coupling fieldnon-ablative radiofrequency skin rejuvenationnon-ablative radiofrequency skin tightening

Autor:innen und Institutionen

  • School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China.
  • Shenzhen Accompany Tech co., ltd, Shenzhen, China.

ORCID-Profile: Yiyou Ma

Förderung

  • SJTU-ZJ BME Research Center

Zitieren

APA

Ma, Y., Wang, N., Li, K., Liang, H., Bai, J., & Ji, X. (2023). Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device. Skin Research and Technology. https://doi.org/10.1111/srt.13472

Vancouver

Ma Y, Wang N, Li K, Liang H, Bai J, Ji X. Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device. Skin Research and Technology. 2023. doi:10.1111/srt.13472

BibTeX
@article{Ma2023,
  author = {Ma, Yiyou and Wang, Nianou and Li, Ke and Liang, Huan and Bai, Jingfeng and Ji, Xiang},
  title = {Effect of geometric parameters of electrodes on skin heating for the design of non‐ablative radiofrequency device},
  journal = {Skin Research and Technology},
  year = {2023},
  doi = {10.1111/srt.13472}
}
Infokarte | EUVIMED