The impact of CSF ‐filled cavities on scalp EEG and its implications
Psychophysiology · 2024-10 · 61 (10)
DOI: 10.1111/psyp.14624 ↗Kurz gefasst
Fachartikel in der Zeitschrift Psychophysiology, online erschienen am 14.06.2024. Verfasst von Vitória Piai und 3 weiteren Autor:innen. Beteiligte Einrichtung: Radboud University, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands. Hauptthemen laut MEDLINE: Electroencephalography, Scalp. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Previous studies have found electroencephalogram (EEG) amplitude and scalp topography differences between neurotypical and neurological/neurosurgical groups, being interpreted at the cognitive level. However, these comparisons are invariably accompanied by anatomical changes. Critical to EEG are the so‐called volume currents, which are affected by the spatial distribution of the different tissues in the head. We investigated the effect of cerebrospinal fluid (CSF)‐filled cavities on simulated EEG scalp data. We simulated EEG scalp potentials for known sources using different volume conduction models: a reference model (i.e., unlesioned brain) and models with realistic CSF‐filled cavities gradually increasing in size. We used this approach for a single source close or far from the CSF‐lesion cavity, and for a scenario with a distributed configuration of sources (i.e., a “cognitive event‐related potential effect”). The magnitude and topography errors between the reference and lesion models were quantified. For the single‐source simulation close to the lesion, the CSF‐filled lesion modulated signal amplitude with more than 17% magnitude error and topography with more than 9% topographical error. Negligible modulation was found for the single source far from the lesion. For the multisource simulations of the cognitive effect, the CSF‐filled lesion modulated signal amplitude with more than 6% magnitude error and topography with more than 16% topography error in a nonmonotonic fashion. In conclusion, the impact of a CSF‐filled cavity cannot be neglected for scalp‐level EEG data. Especially when group‐level comparisons are made, any scalp‐level attenuated, aberrant, or absent effects are difficult to interpret without considering the confounding effect of CSF.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Radboud University, Donders Institute for Brain, Cognition and Behaviour, Nijmegen, The Netherlands.
- NatMEG, Karolinska Institutet, Stockholm, Sweden.
- Clinical Neurophysiology, Technical Medical Centre, Faculty of Science and Technology, University of Twente, Enschede, The Netherlands.
ORCID-Profile: Vitória Piai
Zitieren
APA
Piai, V., Oostenveld, R., Schoffelen, J. M., & Piastra, M. C. (2024). The impact of CSF ‐filled cavities on scalp EEG and its implications. Psychophysiology, 61(10). https://doi.org/10.1111/psyp.14624
Vancouver
Piai V, Oostenveld R, Schoffelen JM, Piastra MC. The impact of CSF ‐filled cavities on scalp EEG and its implications. Psychophysiology. 2024;61(10). doi:10.1111/psyp.14624
BibTeX
@article{Piai2024,
author = {Piai, Vitória and Oostenveld, Robert and Schoffelen, Jan Mathijs and Piastra, Maria Carla},
title = {The impact of CSF ‐filled cavities on scalp EEG and its implications},
journal = {Psychophysiology},
year = {2024},
volume = {61},
number = {10},
doi = {10.1111/psyp.14624}
}
EUVIMED