EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Assessing the effects of head modelling errors and measurement noise on EEG source localization accuracy in preterm newborns: A single‐subject study

Hamed Azizollahi iD, Ardalan Aarabi, Kamran Kazemi, Fabrice Wallois

European Journal of Neuroscience · 2023

DOI: 10.1111/ejn.16060 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Neuroscience, 2023. Verfasst von Hamed Azizollahi und 3 weiteren Autor:innen. Beteiligte Einrichtung: GRAMFC, Inserm U1105, University Research Center (CURS), CHU AMIENS-SITE SUD, Amiens, France. Hauptthemen laut MEDLINE: Models, Neurological, Electroencephalography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The accuracy of electroencephalogram (EEG) source localization is compromised because of head modelling errors. In this study, we investigated the effect of inaccuracy in the conductivity of head tissues and head model structural deficiencies on the accuracy of EEG source analysis in premature neonates. A series of EEG forward and inverse simulations was performed by introducing structural deficiencies into the reference head models to generate test models, which were then used to investigate head modelling errors caused by cerebrospinal fluid (CSF) exclusion, lack of grey matter (GM)–white matter (WM) distinction, fontanel exclusion and inaccuracy in skull conductivity. The modelling errors were computed between forward and inverse solutions obtained using the reference and test models generated for each deficiency. Our results showed that the exclusion of CSF from the head model had a strong widespread effect on the accuracy of the EEG source localization with position errors lower than 4.17 mm. The GM and WM distinction also caused strong localization errors (up to 3.5 mm). The exclusion of fontanels from the head model also strongly affected the accuracy of the EEG source localization for sources located beneath the fontanels with a maximum localization error of 4.37 mm. Similarly, inaccuracies in the skull conductivity caused errors in EEG forward and inverse modelling in sources beneath cranial bones. Our results indicate that the accuracy of EEG source imaging in premature neonates can be largely improved by using head models, which include not only the brain, skull and scalp but also the CSF, GM, WM and fontanels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, NeurologicalElectroencephalographyInfant, NewbornHumansBrainSkullScalp

Stichwörter der Autor:innen

EEG source localizationhead modelling errorneonatal EEGpreterm neonates

Autor:innen und Institutionen

  • GRAMFC, Inserm U1105, University Research Center (CURS), CHU AMIENS-SITE SUD, Amiens, France.
  • Laboratory of Functional Neuroscience and Pathologies (LNFP UR 4559), University Research Center, University Hospital, Amiens, France.
  • Faculty of Medicine, University of Picardy Jules Verne, Amiens, France.
  • Department of Electrical and Electronics Engineering, Shiraz University of Technology, Shiraz, Iran.
  • EFSN Pediatric (Pediatric Nervous System Functional Investigation Unit), Department of Pediatrics, CHU AMIENS-SITE SUD, Amiens, France.

ORCID-Profile: Hamed Azizollahi

Zitieren

APA

Azizollahi, H., Aarabi, A., Kazemi, K., & Wallois, F. (2023). Assessing the effects of head modelling errors and measurement noise on EEG source localization accuracy in preterm newborns: A single‐subject study. European Journal of Neuroscience. https://doi.org/10.1111/ejn.16060

Vancouver

Azizollahi H, Aarabi A, Kazemi K, Wallois F. Assessing the effects of head modelling errors and measurement noise on EEG source localization accuracy in preterm newborns: A single‐subject study. European Journal of Neuroscience. 2023. doi:10.1111/ejn.16060

BibTeX
@article{Azizollahi2023,
  author = {Azizollahi, Hamed and Aarabi, Ardalan and Kazemi, Kamran and Wallois, Fabrice},
  title = {Assessing the effects of head modelling errors and measurement noise on EEG source localization accuracy in preterm newborns: A single‐subject study},
  journal = {European Journal of Neuroscience},
  year = {2023},
  doi = {10.1111/ejn.16060}
}
Kostenlos starten →