EUVIMEDEUVIMED entdecken
Crossref

Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults

Makoto Takenaka, Mark E Pflieger, Tomokatsu Hori, Yudai Iwama, Jumpei Matsumoto, Tsuyoshi Setogawa, Atsushi Shirasawa iD, Hiroshi Nishimaru, Hisao Nishijo iD

Clinical EEG and Neuroscience · 2025

DOI: 10.1177/15500594251323625 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical EEG and Neuroscience, 2025. Verfasst von Makoto Takenaka und 8 weiteren Autor:innen. Beteiligte Einrichtung: System Emotional Science, Faculty of Medicine, University of Toyama, Toyama, Japan. Hauptthemen laut MEDLINE: Electroencephalography, Epilepsy, Brain. Die Arbeit nennt 56 Literaturangaben. Gefördert von: University of East Asia, University of Toyama.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Epilepsy is prevalent in the elderly, whose brain morphologies and skull electrical characteristics differ from those of younger adults. Here, using a multivariate definition of signal-to-noise ratio (SNR), we explored the detectability of epileptic spikes in scalp EEG measurements in elderly by forward simulations of hypersynchronous spikes generated at 78 cortical regions of interest (ROIs) in the presence of background noise.

Methods

Simulated electric potentials were measured at 18, 35, and 70 standard 10–20 electrode positions using three reference methods: infinity reference (INF), common average reference (CAR), and average mastoid reference (M1M2). MRIs of six elderly subjects were used to construct finite element method (FEM) models with age-adjusted skull conductivities.

Results

SNRs of epileptic spikes increased with increasing sizes of the brain electrical source areas, although medial and deep brain regions such as the hippocampus showed lower SNRs, consistent with clinical findings. The SNRs were greater in the 70-channel dataset than in the 18-channel and 35-channel datasets, especially for ROIs located closer to the head surface. In addition, the SNRs were lower for the CAR and M1M2 references than for the ideal INF reference. Moreover, we found comparable results in the standard FEM heads with age-adjusted skull conductivities.

Conclusions

The results provide insights for evaluating scalp EEG data in elderly patients with suspected epilepsy, and suggest that age-adjusted skull conductivity is an important factor for forward models in elderly adults, and that the standard FEM head with age-adjusted skull conductivity can be used when MRIs are not available.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ElectroencephalographyEpilepsyBrainHumansAgedMaleScalpComputer SimulationFemaleSignal-To-Noise RatioMagnetic Resonance ImagingAged, 80 and overBrain Mapping

Stichwörter der Autor:innen

5-tissue finite element method modelelderly peopleelectrode numberelectrode referencesignal-to-noise ratioskull conductivity

Autor:innen und Institutionen

  • System Emotional Science, Faculty of Medicine, University of Toyama, Toyama, Japan.
  • Cortech Solutions, Inc., Wilmington, North Carolina, USA.
  • Department of Neurosurgery, Moriyama Neurological Center Hospital, Tokyo, Japan.
  • Research Center for Idling Brain Science (RCIBS), University of Toyama, Toyama, Japan.
  • Miyuki Giken Co., Ltd., Tokyo, Japan.
  • Faculty of Human Sciences, University of East Asia, Shimonoseki, Japan.

ORCID-Profile: Atsushi Shirasawa, Hisao Nishijo

Förderung

  • University of East Asia
  • University of Toyama

Zitieren

APA

Takenaka, M., Pflieger, M. E., Hori, T., Iwama, Y., Matsumoto, J., Setogawa, T., Shirasawa, A., Nishimaru, H., & Nishijo, H. (2025). Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults. Clinical EEG and Neuroscience. https://doi.org/10.1177/15500594251323625

Vancouver

Takenaka M, Pflieger ME, Hori T, Iwama Y, Matsumoto J, Setogawa T, et al. Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults. Clinical EEG and Neuroscience. 2025. doi:10.1177/15500594251323625

BibTeX
@article{Takenaka2025,
  author = {Takenaka, Makoto and Pflieger, Mark E and Hori, Tomokatsu and Iwama, Yudai and Matsumoto, Jumpei and Setogawa, Tsuyoshi and Shirasawa, Atsushi and Nishimaru, Hiroshi and Nishijo, Hisao},
  title = {Detectability in Scalp EEGs of Epileptic Spikes Emitted from Brain Electrical Sources of Different Sizes and Locations: A Simulation Study Using Realistic Head Models of Elderly Adults},
  journal = {Clinical EEG and Neuroscience},
  year = {2025},
  doi = {10.1177/15500594251323625}
}