EUVIMEDOpdag EUVIMED
Crossref

Measurement of Airway Length in Neonates Using Fiberoptic Bronchoscopy

Vanya Chugh iD, Rohit Kashyap, Charu Bamba

Pediatric Anesthesia · 2026

DOI: 10.1111/pan.70028 ↗

At a glance

Journal article in Pediatric Anesthesia, 2026. Written by Vanya Chugh and 2 co-authors. Institution: Department of Anesthesia and Intensive Care, Vardhman and Mahavir Medical College and Safdarjung Hospital, New Delhi, India. Major MEDLINE topics: Bronchoscopy, Fiber Optic Technology, Airway Management, Trachea. Cited 1 times so far (Crossref); 14 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Introduction

Optimal positioning of the endotracheal tube is a crucial step in the airway management of neonates. Short airway length creates a narrow margin of safety and thus a higher chance of ETT malpositioning. Published literature reports airway length of 5–7.5 cm, which is primarily based on autopsy and radiologic studies. We decided to measure the airway length in neonates undergoing surgeries using flexible fiberoptic bronchoscopy (FFOB). Methodology Sixty full‐term neonates, scheduled for surgery under general anesthesia with endotracheal intubation, were included in the study. Neonates with airway anomalies and anticipated difficult airways were excluded. Airway length was measured using FFOB.

Results

Sixty neonates were included in the study. The mean airway length ± SD was 3.85 ± 0.71 cm. The mean ± SD length in males was 3.87 ± 0.63 cm, and in females was 3.82 ± 0.86 cm. The Spearman rank correlation coefficient of airway length (cm) with age was 0.139, and for weight was 0.130.

Conclusion

Airway length is much smaller in neonates as compared to that reported in the literature. Airway dimensions need reassessment in this population in order to improve safety and effectiveness of neonatal intubation practices.

Subjects

MeSH terms (MEDLINE)

BronchoscopyFiber Optic TechnologyAirway ManagementTracheaHumansInfant, NewbornMaleFemaleIntubation, IntratrachealAnesthesia, General

Author keywords

airway lengthneonatal intubationneonates

Authors and institutions

  • Department of Anesthesia and Intensive Care, Vardhman and Mahavir Medical College and Safdarjung Hospital, New Delhi, India.

ORCID profiles: Vanya Chugh

Cite

APA

Chugh, V., Kashyap, R., & Bamba, C. (2026). Measurement of Airway Length in Neonates Using Fiberoptic Bronchoscopy. Pediatric Anesthesia. https://doi.org/10.1111/pan.70028

Vancouver

Chugh V, Kashyap R, Bamba C. Measurement of Airway Length in Neonates Using Fiberoptic Bronchoscopy. Pediatric Anesthesia. 2026. doi:10.1111/pan.70028

BibTeX
@article{Chugh2026,
  author = {Chugh, Vanya and Kashyap, Rohit and Bamba, Charu},
  title = {Measurement of Airway Length in Neonates Using Fiberoptic Bronchoscopy},
  journal = {Pediatric Anesthesia},
  year = {2026},
  doi = {10.1111/pan.70028}
}
Start for free →