Effect of infusion line connection and infusion line characteristics on start‐up fluid delivery from syringe infusion pumps used for microinfusion
Pediatric Anesthesia · 2025
DOI: 10.1111/pan.15031 ↗At a glance
Journal article in Pediatric Anesthesia, 2025. Written by Markus Weiss and 3 co-authors. Institution: Department of Anesthesia, University Children's Hospital, Zurich, Switzerland. Major MEDLINE topics: Infusion Pumps, Syringes. 22 references. The full text is freely available (open access, CC BY-NC-ND 4.0).
Abstract (original language)
Background
Connecting an infusion line to a closed stopcock results in pressurization of fluid within the syringe infusion pump assembly leading to flow irregularities when opening the stopcock and activating the pump.
Aims
It was the purpose of this study to assess the extent of pressurization under different conditions and its impact on start‐up fluid delivery.
Methods
Intraluminal pressures and start‐up fluid delivery at 1 mL/h flow rate were assessed with connection of the infusion line 1 min (delayed connection) or immediately after purging (immediate connection) using two different infusion lines made from polyvinylchloride (PVC) or polyethylene (PE).
Results
Delayed connection resulted in an increase of intraluminal pressures from zero to 5.1 [4.5 to 5.7] mmHg with the PVC line and from zero to 47.1 [44.8 to 49.3] mmHg with the PE line (mean difference 42.0 [95% CI 39.3–44.7] mmHg; p < .0001). Immediate connection resulted in an increase of intraluminal pressures from zero to 44.3 [41.8–46.8] mmHg with the PVC line and from zero to 61.3 [57.2–65.4] mmHg with the PE line (mean difference 17.0 [95% CI 11.8–22.2] mmHg; p < .0001). The increase in intraluminal pressures was significantly higher with PE lines for both delayed and immediate connection when compared to the PVC lines (mean difference 29.5 [95% CI 19.3–39.7] mmHg; p < .0001). Related fluid volumes delivered at 10 s and 360 s after starting the pump ranged from −252% to 1321% (10 s) of expected infusion volumes and from 59% to 129% (360 s), respectively.
Conclusions
Both, timing of infusion line connection after purging and infusion line characteristics considerably affect intraluminal pressures and start‐up fluid delivery when connecting a new syringe infusion pump assembly to a closed stopcock. Consecutive alterations in drug administration can have considerable hemodynamic consequences when dealing with catecholamine infusions in critically ill patients.
Subjects
MeSH terms (MEDLINE)
Author keywords
Substances
Authors and institutions
- Department of Anesthesia, University Children's Hospital, Zurich, Switzerland.
- Department of Intensive Care, University Hospital, Zurich, Switzerland.
- Department of Neonatology, University Hospital and University of Zurich, Zurich, Switzerland.
- Department of Cardiac Anesthesiology and Intensive Care Medicine, Deutsches Herzzentrum der Charité (DHZC), Berlin, Germany.
- Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
ORCID profiles: Markus Weiss, Pedro David Wendel-Garcia, Vincenzo Cannizzaro, Maren Kleine-Brueggeney
Cite
APA
Weiss, M., Wendel-Garcia, P. D., Cannizzaro, V., & Kleine-Brueggeney, M. (2025). Effect of infusion line connection and infusion line characteristics on start‐up fluid delivery from syringe infusion pumps used for microinfusion. Pediatric Anesthesia. https://doi.org/10.1111/pan.15031
Vancouver
Weiss M, Wendel-Garcia PD, Cannizzaro V, Kleine-Brueggeney M. Effect of infusion line connection and infusion line characteristics on start‐up fluid delivery from syringe infusion pumps used for microinfusion. Pediatric Anesthesia. 2025. doi:10.1111/pan.15031
BibTeX
@article{Weiss2025,
author = {Weiss, Markus and Wendel-Garcia, Pedro David and Cannizzaro, Vincenzo and Kleine-Brueggeney, Maren},
title = {Effect of infusion line connection and infusion line characteristics on start‐up fluid delivery from syringe infusion pumps used for microinfusion},
journal = {Pediatric Anesthesia},
year = {2025},
doi = {10.1111/pan.15031}
}
EUVIMED