Vergleichsstudie in Pacing and Clinical Electrophysiology, 2026. Written by Abdullah Orhan Demirtas and 1 co-authors. Institution: Department of Cardiology, Adana City Training and Research Hospital Adana, Adana, Türkiye. Major MEDLINE topics: Ventricular Premature Complexes, Catheter Ablation. 18 references. The full text is freely available in PubMed Central.

AstrattSubjectsDettalji biblijografiċiCiteRelated studies

Abstract (original language)

Background

Catheter ablation of premature ventricular contractions (PVCs) is an effective treatment modality, but traditionally involves fluoroscopy, which poses radiation risks. Recently, zero‐fluoroscopy (ZF) techniques have emerged as a safer alternative, especially in young patients and those requiring multiple procedures.

Methods

This retrospective, single‐center study evaluated 150 patients who underwent PVC ablation between January 2023 and March 2025. Patients were divided into two groups: those treated with ZF ( n = 75) and conventional fluoroscopy (CF) ( n = 75). Procedural characteristics, procedure time, success rates, and complications were compared.

Results

Acute procedural success was achieved in 79.3% overall, with comparable rates between ZF and CF groups (78.7% vs. 80.0%, p = 0.84). The median procedure time was similar (88 vs. 90 min, p = 0.14), and no significant differences were observed in complication rates (4.0% vs. 4.0%, p = 1.00). Stratified analysis revealed longer procedure times in anatomically complex PVC origins, particularly in LV‐superior and summit regions ( p < 0.001), whereas RV‐inferior PVCs showed the highest success (90%) and shortest duration ( p < 0.05). Univariate logistic regression identified a higher PVC burden and a longer procedure time as predictors of procedural failure. No coronary or atrioventricular conduction injury occurred in either group.

Conclusion

Zero‐fluoroscopy PVC ablation is a safe and effective alternative to conventional methods. Despite longer durations in anatomically complex cases, the ZF approach avoids radiation without compromising outcomes.

Subjects

MeSH terms (MEDLINE)

Ventricular Premature ComplexesCatheter AblationHumansFluoroscopyRetrospective StudiesFemaleMaleMiddle AgedTreatment OutcomeAdult

Author keywords

catheter ablationelectrophysiologic studypremature ventricular contraction

Authors and institutions

  • Department of Cardiology, Adana City Training and Research Hospital Adana, Adana, Türkiye.
  • Necmettin Erbakan University, School of Medicine, Konya, Türkiye.

ORCID profiles: Abdullah Orhan Demirtas, Ahmet Taha Sahin

Cite

APA

Demirtas, A. O., & Sahin, A. T. (2026). Zero‐Fluoroscopy Versus Conventional Catheter Ablation for Premature Ventricular Contractions. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70248

Vancouver

Demirtas AO, Sahin AT. Zero‐Fluoroscopy Versus Conventional Catheter Ablation for Premature Ventricular Contractions. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70248

BibTeX
@article{Demirtas2026,
  author = {Demirtas, Abdullah Orhan and Sahin, Ahmet Taha},
  title = {Zero‐Fluoroscopy Versus Conventional Catheter Ablation for Premature Ventricular Contractions},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70248}
}
Start for free →