Multipolar radiofrequency ablation: Early experience with a novel approach to target intramural ventricular arrhythmias
Heart Rhythm · 2026-08 · 23 (8) · 1761-1772
DOI: 10.1016/j.hrthm.2025.08.005 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Heart Rhythm, 2026-08. Verfasst von Maher Bazzi und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, University of Vermont Medical Center, Burlington, Vermont. Electronic address: maher.bazzi@uvmhealth.org. Hauptthemen laut MEDLINE: Tachycardia, Ventricular, Catheter Ablation, Ventricular Premature Complexes, Heart Ventricles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Conventional radiofrequency ablation (RFA) may fail to treat ventricular arrhythmias (VAs) if the target is located deep within the myocardium. We have previously demonstrated successful treatment of intramural VAs using multipolar ablation (MPA). OBJECTIVE: To evaluate the efficacy of MPA as a means to treat refractory VAs. Accordingly, we herein report a series of patients with refractory VAs treated with MPA. METHODS: This observational retrospective case series included 31 consecutive patients who underwent 36 MPA procedures for premature ventricular contractions (n = 20) and ventricular tachycardia (n = 16). All patients exhibited evidence of intramural origin by defined mapping criteria. Two or more mapping electrodes were incorporated into the ablation circuit as return poles. Ablation-return configurations included left ventricle (LV) endocardium-LV epicardium, LV endocardium-right ventricle (RV) endocardium, and LV or RV endocardium-epicardial vein tributaries. RESULTS: A total of 151 MPA lesions were delivered with an RFA of 60 s, power of 22 W, initial current of 379 mA, and impedance drop of 19 Ω. Technical limitations of lesion delivery included high impedance in coronary sinus branches and char formation on return electrodes. Acute success was observed in 34 cases (94%), near-term success in 25 cases (69%), and long-term success in 23 cases (70%). There were no major complications. CONCLUSION: MPA may facilitate arrhythmia control in patients with intramural VAs. Nevertheless, additional studies are necessary to better evaluate MPA safety and efficacy profiles, with further preclinical work and larger clinical studies required.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, University of Vermont Medical Center, Burlington, Vermont. Electronic address: maher.bazzi@uvmhealth.org.
- Department of Cardiology, Massachusetts General Hospital, Boston, Massachusetts.
- Department of Cardiology, University of Vermont Medical Center, Burlington, Vermont.
- Abbott Medical, St Paul, Minnesota.
Zitieren
APA
Bazzi, M., Venn, R., Pipilas, D., Habel, N., Hauf, T., Nguyen, T., Cagnon, P., Hucker, W., Michaud, G., Thompson, N., & Hanley, A. (2026). Multipolar radiofrequency ablation: Early experience with a novel approach to target intramural ventricular arrhythmias. Heart Rhythm, 23(8), 1761-1772. https://doi.org/10.1016/j.hrthm.2025.08.005
Vancouver
Bazzi M, Venn R, Pipilas D, Habel N, Hauf T, Nguyen T, et al. Multipolar radiofrequency ablation: Early experience with a novel approach to target intramural ventricular arrhythmias. Heart Rhythm. 2026;23(8):1761-1772. doi:10.1016/j.hrthm.2025.08.005
BibTeX
@article{Bazzi2026,
author = {Bazzi, Maher and Venn, Rachael and Pipilas, Daniel and Habel, Nicole and Hauf, Tyler and Nguyen, Tri and Cagnon, Paul and Hucker, William and Michaud, Gregory and Thompson, Nathaniel and Hanley, Alan},
title = {Multipolar radiofrequency ablation: Early experience with a novel approach to target intramural ventricular arrhythmias},
journal = {Heart Rhythm},
year = {2026},
volume = {23},
number = {8},
pages = {1761--1772},
doi = {10.1016/j.hrthm.2025.08.005}
}
EUVIMED