EUVIMEDEUVIMED entdecken
Open Access

Influencing Factors and Prediction of Complications After Implantation of Cardiac Electronic Devices

Chuan-Jiang Chen, Ming Gui, Mei-Ping Lin, Shuping Huang, Yiting Tan, Xinyan He, Karina Yuanyuan Yu, Yumei Xue iD, Wenjing Zhao, Hai Deng iD, Xudong Liu iD

Pacing and Clinical Electrophysiology · 2026

DOI: 10.1111/pace.70228 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2026. Verfasst von Chuan-Jiang Chen und 10 weiteren Autor:innen. Beteiligte Einrichtung: School of Public Health, Guangdong Pharmaceutical University, Guangzhou, China. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Pacemaker, Artificial, Postoperative Complications, Hematoma. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Guangdong Basic and Applied Basic Research Foundation, Shenzhen Medical Research Fund, Clinical Research Fund of Guangdong Medical Association.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Cardiac implantable electronic device (CIED) related complications occur frequently. Given the uncertainties, a comprehensive investigation of predictive factors is crucial. This study aimed to identify the determinants influencing the occurrence of CIED‐related complications and to evaluate their predictive capability for the onset of CIED‐related complications.

Methods

This retrospective cohort study recruited 870 patients who underwent CIED implantation. The primary outcome was overall complications, and the secondary was pocket hematomas (PH). Logistic regression model was used to estimate the odds ratio (OR) with the 95% confidence interval (CI), and to establish the prediction models for all complications and PH.

Results

43 cases (4.95%) developed complications during follow‐up, including 24 (2.8%) PH and 19 others. After adjusted for potential confounders, body mass index (BMI), having diabetes and chronic kidney disease (CKD), usage of anticoagulants and antiplatelets, device type, device replacement, and device electrode quantities were all associated with the risk of both the complications and PH. The prediction model with these variables displayed a good performance in predicting the complications occurrence, with AUC and C‐statistic being 0.886 and 0.886 in training dataset, and 0.780 and 0.761 in the test dataset. Similar good performance in predicting PH onset were also observed.

Conclusion

The results indicate that BMI, diabetes, CKD, anticoagulants, antiplatelets, device types, device replacement, and device electrode quantities are critical risk factors, which can help predict the onset of the complications and PH.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Defibrillators, ImplantablePacemaker, ArtificialPostoperative ComplicationsHematomaHumansFemaleRetrospective StudiesMaleRisk FactorsAgedMiddle Aged

Stichwörter der Autor:innen

Cardiac implantable electronic deviceCohort studyComplicationPredictionRisk factors

Autor:innen und Institutionen

  • School of Public Health, Guangdong Pharmaceutical University, Guangzhou, China.
  • Department of Cardiology, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital, Guangdong Academy of Medical Science, Southern Medical University, Guangzhou, China.
  • The Department of Medicine and Therapeutics, Prince of Wales Hospital, Shatin, Hong Kong, SAR, China.
  • School of Public Health and Emergency Management, Southern University of Science and Technology, Shenzhen, China.

ORCID-Profile: Yumei Xue, Hai Deng, Xudong Liu

Förderung

  • Guangdong Basic and Applied Basic Research Foundation
  • Shenzhen Medical Research Fund
  • Clinical Research Fund of Guangdong Medical Association
  • Basic and Applied Basic Research Foundation of Guangdong Province

Zitieren

APA

Chen, C. J., Gui, M., Lin, M. P., Huang, S., Tan, Y., He, X., Yu, K. Y., Xue, Y., Zhao, W., Deng, H., & Liu, X. (2026). Influencing Factors and Prediction of Complications After Implantation of Cardiac Electronic Devices. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70228

Vancouver

Chen CJ, Gui M, Lin MP, Huang S, Tan Y, He X, et al. Influencing Factors and Prediction of Complications After Implantation of Cardiac Electronic Devices. Pacing and Clinical Electrophysiology. 2026. doi:10.1111/pace.70228

BibTeX
@article{Chen2026,
  author = {Chen, Chuan-Jiang and Gui, Ming and Lin, Mei-Ping and Huang, Shuping and Tan, Yiting and He, Xinyan and Yu, Karina Yuanyuan and Xue, Yumei and Zhao, Wenjing and Deng, Hai and Liu, Xudong},
  title = {Influencing Factors and Prediction of Complications After Implantation of Cardiac Electronic Devices},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2026},
  doi = {10.1111/pace.70228}
}
Kostenlos starten →