Outcomes of an expedited same-day discharge protocol following cardiac implantable electronic device (CIED) implantation
Journal of Interventional Cardiac Electrophysiology · 2024
DOI: 10.1007/s10840-024-01734-w ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, 2024. Verfasst von Satish Misra und 12 weiteren Autor:innen. Beteiligte Einrichtung: Sanger Heart and Vascular Institute, 1237 Harding Place, Charlotte, NC, 28204, USA. satish.misra@atriumhealth.org. Hauptthemen laut MEDLINE: Defibrillators, Implantable, Patient Discharge, Postoperative Complications, Prosthesis Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: With increasing constraints on healthcare resources, greater attention is being focused on improved resource utilization. Prior studies have demonstrated safety of same-day discharge following CIED implantation but are limited by vague protocols with long observation periods. In this study, we evaluate the safety of an expedited 2 hour same-day discharge protocol following CIED implantation. METHODS: Patients undergoing CIED implantation at three centers between 2015 and 2021 were included. Procedural, demographic, and adverse event data were abstracted from the electronic health record. Patients were divided into same-day discharge (SDD) and delayed discharge (DD) cohorts. The primary outcome was complications including lead malfunction requiring revision, pneumothorax, hemothorax, lead dislodgement, lead perforation with tamponade, and mortality within 30 days of procedure. Outcomes were compared between the two cohorts using the χ2 test. RESULTS: A total of 4543 CIED implantation procedures were included with 1557 patients (34%) in the SDD cohort. SDD patients were comparatively younger, were more likely to be male, and had fewer comorbidities than DD patients. Among SDD patients, the mean time to post-operative chest X-ray was 2.6 h. SDD had lower rates of complications (1.3% vs 2.1%, p = 0.0487) and acute care utilization post-discharge (9.6% vs 14.0%, p < 0.0001). There was no difference in the 90-day infection rate between the cohorts. CONCLUSIONS: An expedited 2 hour same-day discharge protocol is safe and effective with low rates of complications, infection, and post-operative acute care utilization.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Sanger Heart and Vascular Institute, 1237 Harding Place, Charlotte, NC, 28204, USA. satish.misra@atriumhealth.org.
- Sanger Heart and Vascular Institute, 1237 Harding Place, Charlotte, NC, 28204, USA.
Zitieren
APA
Misra, S., Swayampakala, K., Rajwani, A., Davenport, E., Fedor, J., Saxonhouse, S., Holshouser, J., Patel, N., Thompson, J., Beaty, E., Jain, M., Powell, B., & Mehta, R. (2024). Outcomes of an expedited same-day discharge protocol following cardiac implantable electronic device (CIED) implantation. Journal of Interventional Cardiac Electrophysiology. https://doi.org/10.1007/s10840-024-01734-w
Vancouver
Misra S, Swayampakala K, Rajwani A, Davenport E, Fedor J, Saxonhouse S, et al. Outcomes of an expedited same-day discharge protocol following cardiac implantable electronic device (CIED) implantation. Journal of Interventional Cardiac Electrophysiology. 2024. doi:10.1007/s10840-024-01734-w
BibTeX
@article{Misra2024,
author = {Misra, Satish and Swayampakala, Kamala and Rajwani, Aparna and Davenport, Elizabeth and Fedor, John and Saxonhouse, Sherry and Holshouser, John and Patel, Neel and Thompson, Joseph and Beaty, Elijah and Jain, Manish and Powell, Brian and Mehta, Rohit},
title = {Outcomes of an expedited same-day discharge protocol following cardiac implantable electronic device (CIED) implantation},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2024},
doi = {10.1007/s10840-024-01734-w}
}