EUVIMEDOpdag EUVIMED
Crossref

Efficacy of Delivery Catheter for the Right Ventricular Septal Placement of a Defibrillator Lead

Hiroyuki Kato iD, Koudai Yamazaki, Taku Sakurai, Shinji Yamazoe, Kazuhito Tsuzuki, Kazumasa Suga, Tomoyuki Ota, Hisashi Murakami, Kenji Kada, Naoya Tsuboi, Satoshi Yanagisawa, Yasuya Inden and 1 more

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.70060 ↗

At a glance

Journal article in Pacing and Clinical Electrophysiology, 2025. Written by Hiroyuki Kato and 12 co-authors. Institution: Department of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan. Major MEDLINE topics: Defibrillators, Implantable, Electrodes, Implanted, Prosthesis Implantation. 33 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Right ventricular (RV) septal placement of implantable cardioverter‐defibrillator (ICD) leads has been proposed as an alternative to conventional apical placement. However, optimal techniques for accurate septal defibrillator lead implantation remain to be established.

Methods

This single‐center, retrospective study analyzed 37 patients with cardiomyopathy who underwent ICD implantation with intended RV septal defibrillator lead placement. Patients were categorized into two groups based on the implantation technique: delivery catheter ( n = 7) or stylet system ( n = 30). Myocardial current of injury (COI) monitoring was used in the delivery catheter group to guide lead fixation. The lead position was assessed by cardiac computed tomography, and procedural outcomes were compared.

Results

Accurate RV septal lead placement was achieved in 100% of the delivery catheter group compared to 60% in the stylet group ( p = 0.047). The delivery catheter group also demonstrated significantly shorter lead implantation time (median 9 vs. 17 min, p = 0.016) and total fluoroscopy time (median 15 vs. 29 min, p = 0.009). Lead parameters and complication rates were comparable. A subclinical pericardial effusion was identified in one patient from the stylet group, in whom the lead was positioned in the RV free wall.

Conclusion

The use of the delivery catheter with COI monitoring significantly enhanced the accuracy and efficiency of RV septal defibrillator lead implantation without compromising safety. This technique may offer procedural advantages over conventional stylet‐based methods in patients with cardiomyopathy. Prospective studies are needed to establish more definitively the usefulness and safety of this approach.

Subjects

MeSH terms (MEDLINE)

Defibrillators, ImplantableElectrodes, ImplantedProsthesis ImplantationHumansMaleFemaleRetrospective StudiesMiddle AgedTreatment OutcomeAged

Author keywords

cardiac perforationcardiomyopathycurrent of injuryimplantable cardioverter defibrillatorpacemakerseptal pacingstylet system

Authors and institutions

  • Department of Cardiology, Japan Community Healthcare Organization Chukyo Hospital, Nagoya, Japan.
  • Department of Cardiology, Nagoya University Graduate School of Medicine, Nagoya, Japan.

ORCID profiles: Hiroyuki Kato

Cite

APA

Kato, H., Yamazaki, K., Sakurai, T., Yamazoe, S., Tsuzuki, K., Suga, K., Ota, T., Murakami, H., Kada, K., Tsuboi, N., Yanagisawa, S., Inden, Y., & Murohara, T. (2025). Efficacy of Delivery Catheter for the Right Ventricular Septal Placement of a Defibrillator Lead. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70060

Vancouver

Kato H, Yamazaki K, Sakurai T, Yamazoe S, Tsuzuki K, Suga K, et al. Efficacy of Delivery Catheter for the Right Ventricular Septal Placement of a Defibrillator Lead. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70060

BibTeX
@article{Kato2025,
  author = {Kato, Hiroyuki and Yamazaki, Koudai and Sakurai, Taku and Yamazoe, Shinji and Tsuzuki, Kazuhito and Suga, Kazumasa and Ota, Tomoyuki and Murakami, Hisashi and Kada, Kenji and Tsuboi, Naoya and Yanagisawa, Satoshi and Inden, Yasuya and Murohara, Toyoaki},
  title = {Efficacy of Delivery Catheter for the Right Ventricular Septal Placement of a Defibrillator Lead},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.70060}
}
Start for free →