Near‐Zero Fluoroscopy Ablation Workflow With a Circular Multielectrode Pulsed‐Field Ablation Catheter

Kennosuke Yamashita iD, Yohei Kikuchi, Keita Yoshiyama, Daiki Kumazawa, Yosuke Mizuno, Kosuke Onodera, Takehiro Nomura

Pacing and Clinical Electrophysiology · 2025

DOI: 10.1111/pace.70046 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pacing and Clinical Electrophysiology, 2025. Verfasst von Kennosuke Yamashita und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Medicine, Heart Rhythm Center, Sendai Kosei Hospital, Miyagi, Japan. Hauptthemen laut MEDLINE: Catheter Ablation, Atrial Fibrillation, Pulmonary Veins. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 11 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Pulmonary vein isolation (PVI) using pulsed field ablation (PFA) is effective for treating atrial fibrillation (AF) but often requires fluoroscopy, posing risks of radiation exposure. Using a circular multi‐electrode PulseSelect catheter along with 3D electroanatomical mapping (3D‐EAM) and intracardiac echocardiography (ICE) enables pulmonary vein isolation (PVI) with near‐zero fluoroscopy.

Methods

All procedures were managed under general anesthesia. Following transseptal puncture, pre‐mapping was conducted using a multi‐electrode catheter. Based on these initial mappings, the PulseSelect catheter and guiding wire were visualized on the 3D‐EAM to perform PVI. After the procedure, post‐mapping was carried out to confirm that there was no electrical reconnection in the treated areas.

Results

The median times for isolation of the left and right pulmonary veins were 9.0 and 11.0 min, respectively. Total procedure time averaged 48.5 min, with fluoroscopy time limited to 0.1 min for initial registration. Pre‐ and post‐mapping indicated minimal deviations in catheter positioning, demonstrating controlled ablation without significant procedural complications. Holter monitoring at three months showed a low recurrence rate of atrial arrhythmias.

Conclusion

The near‐zero fluoroscopy PFA workflow using the PulseSelect catheter, combined with 3D‐EAM and ICE, significantly reduces radiation exposure, enhances procedural safety, and maintains efficacy in AF ablation. This approach confirms the feasibility of reducing reliance on fluoroscopy while ensuring accurate and safe ablation outcomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Catheter AblationAtrial FibrillationPulmonary VeinsHumansFluoroscopyWorkflowMaleFemaleMiddle AgedElectrodesEquipment DesignAged

Stichwörter der Autor:innen

atrial fibrillationintracardiac echocardiographypulmonary vein isolationpulsed field ablationthree‐dimensional electroanatomical mappingzero‐fluoroscopy

Autor:innen und Institutionen

  • Department of Cardiovascular Medicine, Heart Rhythm Center, Sendai Kosei Hospital, Miyagi, Japan.

ORCID-Profile: Kennosuke Yamashita

Zitieren

APA

Yamashita, K., Kikuchi, Y., Yoshiyama, K., Kumazawa, D., Mizuno, Y., Onodera, K., & Nomura, T. (2025). Near‐Zero Fluoroscopy Ablation Workflow With a Circular Multielectrode Pulsed‐Field Ablation Catheter. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.70046

Vancouver

Yamashita K, Kikuchi Y, Yoshiyama K, Kumazawa D, Mizuno Y, Onodera K, et al. Near‐Zero Fluoroscopy Ablation Workflow With a Circular Multielectrode Pulsed‐Field Ablation Catheter. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.70046

BibTeX
@article{Yamashita2025,
  author = {Yamashita, Kennosuke and Kikuchi, Yohei and Yoshiyama, Keita and Kumazawa, Daiki and Mizuno, Yosuke and Onodera, Kosuke and Nomura, Takehiro},
  title = {Near‐Zero Fluoroscopy Ablation Workflow With a Circular Multielectrode Pulsed‐Field Ablation Catheter},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.70046}
}
Kostenlos starten →