Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients
Journal of Interventional Cardiac Electrophysiology · 03.02.2025 · 68 (4) · 877-884
DOI: 10.1007/s10840-025-01981-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Interventional Cardiac Electrophysiology, online erschienen am 03.02.2025. Verfasst von M Borlich und 8 weiteren Autor:innen. Beteiligte Einrichtung: Heart and Vascular Center, Segeberger Kliniken, Am Kurpark 1, 23795, Bad Segeberg, Germany. martin.borlich@segebergerkliniken.de. Hauptthemen laut MEDLINE: Atrial Fibrillation, Pulmonary Veins, Catheter Ablation. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
BACKGROUND: Catheter ablation is a standard atrial fibrillation (AF) treatment, traditionally using radiofrequency (RF) or cryoablation, which carries the risk of damaging nearby structures. Pulsed field ablation (PFA) offers partly tissue-selective energy application with minimal collateral damage. This study evaluated a near-zero fluoroscopy workflow with the novel VARIPULSE™ catheter, combining advanced mapping for optimized PFA delivery and reduced radiation. Here, we investigate the safety, efficiency, and effectiveness of this approach in the first 35 patients treated. OBJECTIVE: This study aimed to assess the procedural characteristics, safety, and acute efficacy of pulmonary vein isolation (PVI) using the VARIPULSE™ PFA catheter in patients with AF, while specifically evaluating a near-zero fluoroscopy workflow to minimize radiation exposure during the procedure. METHODS: Thirty-five consecutive patients with paroxysmal or persistent AF underwent pulmonary vein isolation (PVI) using the VARIPULSE™ PFA catheter. Procedures were conducted under general anesthesia or deep sedation. Key procedural endpoints included acute pulmonary vein isolation, total procedure time, left atrial (LA) dwell time, fluoroscopy time and dose, and safety outcomes, with a focus on assessing the feasibility of a near-zero fluoroscopy workflow. RESULTS: Thirty patients underwent near-zero fluoroscopy atrial fibrillation ablation using the novel VARIPULSE™ Pulsed Field Ablation catheter. Patients had a median age of 70 years and typical cardiovascular comorbidities, with 54% presenting with paroxysmal AF. Thirty-three of 35 patients (94%) had a normal left ventricular systolic function (> 60%). The median CHA2DS2-VA score was 2 (IQR 1-3.75). Sinus rhythm was observed in 66% of cases at procedure start. Median fluoroscopy time was 0.8 min, total median procedure time 53 min, median LA dwell time 38 min, and median fluoroscopy dose 20.4 µGym2. Pulmonary vein isolation was achieved in 100% of cases without radiofrequency touch-up. No major complications occurred. CONCLUSION: The VARIPULSE™ Pulsed Field Ablation system enables an efficient, nearly fluoroscopy-free atrial fibrillation ablation with a simple, easily integrable workflow in the electrophysiology lab. Complete pulmonary vein isolation was achieved in all cases without radiofrequency touch-ups, and the procedure was safe with no major complications. This demonstrates the potential for widespread adoption of this technology and workflow.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Heart and Vascular Center, Segeberger Kliniken, Am Kurpark 1, 23795, Bad Segeberg, Germany. martin.borlich@segebergerkliniken.de.
- Heart and Vascular Center, Segeberger Kliniken, Am Kurpark 1, 23795, Bad Segeberg, Germany.
- Department of Cardiology, University of Oldenburg, Oldenburg, Germany.
Zitieren
APA
Borlich, M., Groschke, S., Wietgrefe, J., Witt, F., Paulssen, A., Fichtlscherer, S., Elsässer, A., Nef, H., & Iden, L. (2025). Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients. Journal of Interventional Cardiac Electrophysiology, 68(4), 877-884. https://doi.org/10.1007/s10840-025-01981-5
Vancouver
Borlich M, Groschke S, Wietgrefe J, Witt F, Paulssen A, Fichtlscherer S, et al. Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients. Journal of Interventional Cardiac Electrophysiology. 2025;68(4):877-884. doi:10.1007/s10840-025-01981-5
BibTeX
@article{Borlich2025,
author = {Borlich, M and Groschke, S and Wietgrefe, J and Witt, F and Paulssen, A and Fichtlscherer, S and Elsässer, A and Nef, H and Iden, L},
title = {Near-zero fluoroscopy workflow for pulmonary vein isolation in atrial fibrillation using a variable loop, 3D-integrated circular PFA catheter (Varipulse™): initial single-center experience with the first 35 patients},
journal = {Journal of Interventional Cardiac Electrophysiology},
year = {2025},
volume = {68},
number = {4},
pages = {877--884},
doi = {10.1007/s10840-025-01981-5}
}
EUVIMED