Safety, Effectiveness, and Clinical Workflow with a Balloon-Based Pulsed Field Ablation System
Cardiac Electrophysiology Clinics · 2025
DOI: 10.1016/j.ccep.2025.02.012 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Cardiac Electrophysiology Clinics, 2025. Verfasst von Monica Lo und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrophysiology, Arkansas Heart Hospital, 1701 South Shackleford Road, Little Rock, AR 72211, USA. Electronic address: monica.lo@arhe…. Hauptthemen laut MEDLINE: Workflow, Catheter Ablation, Atrial Fibrillation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
A balloon-based pulsed field ablation (PFA) system with tissue proximity and mapping integration is currently undergoing clinical study. The initial 47 cases performed by a single operator identified important procedural workflow and system features that allow for the efficient adoption of this new catheter ablation technology resulting in an average procedure time including a 20 minute waiting period of 106.4 ± 21.1 minutes, with an average of 18.2 ± 3.1 applications per patient. This initial clinical study experience demonstrated this PFA system was safe and acutely effective in pulmonary vein isolation for the treatment of atrial fibrillation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrophysiology, Arkansas Heart Hospital, 1701 South Shackleford Road, Little Rock, AR 72211, USA. Electronic address: monica.lo@arheart.com.
- Abbott, 5050 Nathan Lane North, Plymouth, MN 55442, USA.
Zitieren
APA
Lo, M., Miller, A., & Leverence, K. (2025). Safety, Effectiveness, and Clinical Workflow with a Balloon-Based Pulsed Field Ablation System. Cardiac Electrophysiology Clinics. https://doi.org/10.1016/j.ccep.2025.02.012
Vancouver
Lo M, Miller A, Leverence K. Safety, Effectiveness, and Clinical Workflow with a Balloon-Based Pulsed Field Ablation System. Cardiac Electrophysiology Clinics. 2025. doi:10.1016/j.ccep.2025.02.012
BibTeX
@article{Lo2025,
author = {Lo, Monica and Miller, Amber and Leverence, Kerri},
title = {Safety, Effectiveness, and Clinical Workflow with a Balloon-Based Pulsed Field Ablation System},
journal = {Cardiac Electrophysiology Clinics},
year = {2025},
doi = {10.1016/j.ccep.2025.02.012}
}
EUVIMED