Journal article in Pacing and Clinical Electrophysiology, published online on 2025-09-16. Written by Cord-Friedrich Niehaus and 18 co-authors. Institution: Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany, Herz- und Diabeteszentrum NRW, Ruhr-Un…. Major MEDLINE topics: Electrodes, Implanted, Bundle-Branch Block, Bundle of His, Cardiac Pacing, Artificial. Cited 1 times so far (Crossref); 14 references. The full text is freely available (open access, CC BY 4.0).

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Aims

Left bundle branch area pacing (LBBAP) has emerged as an alternative to cardiac stimulation via right ventricular pacing and cardiac resynchronization therapy using coronary sinus leads. The approach utilizes dedicated three‐dimensional guiding catheters for lead placement. Our objective was to evaluate the feasibility and safety of a simplified approach of implantation of an LBBAP electrode without a dedicated guiding catheter.

Methods

This was a prospective single‐center proof‐of‐concept evaluation. Patients with an indication for dual‐chamber pacemaker implantation were consecutively enrolled. All patients received ventricular lead placement with a commercially available stylet‐driven pacemaker lead. LBBAP was attempted without the use of a dedicated guiding catheter but with the help of a manually three‐dimensionally pre‐curved stylet.

Results

A total of 24 patients were analyzed. Procedure and fluoroscopy durations were 61 ± 12 min and 7.4 ± 3.9 min, while LBBAP lead placement was successful in 19 patients (79%). In these patients, the V6‐R‐wave peak time was 74 ± 11 ms, the V1V6 interpeak interval was 51 ± 11 ms, and QRS width during unipolar stimulation was 123 ± 14 ms. No complications attributed to the transseptal route of the pacing lead occurred. After a mean follow‐up of 104 ± 20 days, there was no significant change in QRS widths (123 ± 15 ms, p = 0.94), V6‐R wave peak time (70 ± 11 ms, p = 0.3), and V1V6 interpeak interval (45 ± 10 ms; p = 0.12).

Conclusion

Implantation of an LBBAP electrode without the use of a dedicated three‐dimensional sheath is feasible and safe in a high proportion of patients. Further studies are necessary to define the impact of this technique for potential use in clinical routine.

Subjects

MeSH terms (MEDLINE)

Electrodes, ImplantedBundle-Branch BlockBundle of HisCardiac Pacing, ArtificialPacemaker, ArtificialProsthesis ImplantationHumansFemaleMaleProspective StudiesAgedFeasibility StudiesProof of Concept StudyMiddle Aged

Author keywords

implantation techniqueleft bundle branch pacingstylet‐driven

Authors and institutions

  • Clinic for Electrophysiology, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany, Herz- und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Clinic For Internal Medicine/Cardiology, St. Marienhospital Vechta, Vechta, Germany.
  • Clinic for Thoracic and Cardiovascular Surgery, Herz -und Diabeteszentrum NRW, Ruhr-Universität Bochum, Bad Oeynhausen, Germany.
  • Clinic For Internal Medicine/Cardiology and Intensive Care Medicine, Niels-Stensen-Kliniken, Marienhospital Osnabrück, Osnabrück, Germany.
  • Clinic For Cardiology and Angiology, GZO Spital Wetzikon, Wetzikon, Zurich, Switzerland.

Cite

APA

Niehaus, C. F., Imnadze, G., Eitz, T., Weglage, H., Sciacca, V., Lucas, P., Antonyan, L., Beyer, S. E., Akkaya, E., Waezsada, E., Bocchini, Y., Hamriti, M. E., Winnik, S., Guckel, D., Didenko, M., Khalaph, M., Sohns, C., Sommer, P., & Fink, T. (2025). Initial Experience With Implantation Left Bundle Branch Pacing Leads Without a Dedicated Three‐Dimensional Sheath. Pacing and Clinical Electrophysiology, 48(10), 1086-1093. https://doi.org/10.1111/pace.70039

Vancouver

Niehaus CF, Imnadze G, Eitz T, Weglage H, Sciacca V, Lucas P, et al. Initial Experience With Implantation Left Bundle Branch Pacing Leads Without a Dedicated Three‐Dimensional Sheath. Pacing and Clinical Electrophysiology. 2025;48(10):1086-1093. doi:10.1111/pace.70039

BibTeX
@article{Niehaus2025,
  author = {Niehaus, Cord-Friedrich and Imnadze, Guram and Eitz, Thomas and Weglage, Heinrich and Sciacca, Vanessa and Lucas, Philipp and Antonyan, Lilit and Beyer, Sebastian E and Akkaya, Ersan and Waezsada, Elias and Bocchini, Yuri and Hamriti, Mustapha El and Winnik, Stephan and Guckel, Denise and Didenko, Maxim and Khalaph, Moneeb and Sohns, Christian and Sommer, Philipp and Fink, Thomas},
  title = {Initial Experience With Implantation Left Bundle Branch Pacing Leads Without a Dedicated Three‐Dimensional Sheath},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  volume = {48},
  number = {10},
  pages = {1086--1093},
  doi = {10.1111/pace.70039}
}
Start for free →