Fallbericht in Pacing and Clinical Electrophysiology, 2025. Written by Chandan Sharma and 1 co-authors. Institution: Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India. Major MEDLINE topics: Device Removal, Pacemaker, Artificial, Electrodes, Implanted, Prosthesis-Related Infections. 5 references.

AbstractSubjectsBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Background

Transvenous lead extraction (TLE) is recognized as an effective method of lead extraction, but can be challenging with old and tined pacemaker leads. Case Summary We present the case of a 44‐year‐old male with cardiovascular implantable electronic device (CIED) infection who underwent TLE of his 15‐year‐old tined pacemaker leads using a novel approach. A carotid shuttle sheath with the tip fashioned into a bevel shape was used as a makeshift dilator to dissect and free the leads from adhesions. A bioptome, introduced through the TightRail sheath, was employed to dislodge the right ventricular (RV) lead tip, while a snare introduced subsequently through the same access was used to grip the distal end of the RV lead. The lead was extracted using the snare without the need for additional femoral or jugular access.

Conclusion

To the best of our knowledge, the use of this bioptome and snare technique, through the TightRail sheath, without employing femoral or jugular access for lead extraction, has not been previously reported. This case highlights the importance of innovative techniques in successfully addressing challenging TLE cases.

Subjects

MeSH terms (MEDLINE)

Device RemovalPacemaker, ArtificialElectrodes, ImplantedProsthesis-Related InfectionsHumansMaleAdultDevice Lead Extraction

Author keywords

TightRailbioptomesnaretransvenous lead extraction

Authors and institutions

  • Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India.

ORCID profiles: Chandan Sharma

Cite

APA

Sharma, C., & Sharma, G. (2025). Innovative Approach to Transvenous Lead Extraction: Bioptome and Snare Technique Without Additional Venous Access. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/pace.15191

Vancouver

Sharma C, Sharma G. Innovative Approach to Transvenous Lead Extraction: Bioptome and Snare Technique Without Additional Venous Access. Pacing and Clinical Electrophysiology. 2025. doi:10.1111/pace.15191

BibTeX
@article{Sharma2025,
  author = {Sharma, Chandan and Sharma, Gautam},
  title = {Innovative Approach to Transvenous Lead Extraction: Bioptome and Snare Technique Without Additional Venous Access},
  journal = {Pacing and Clinical Electrophysiology},
  year = {2025},
  doi = {10.1111/pace.15191}
}
Start for free →